• Have the technical inspection of the fryer (deep fryer) performed at least once a year, with
particular emphasis on the operation and tightness of the gas installation. This inspection should be
carried out at the manufacturer's website or in an establishment with appropriate qualifications and
equipment with the required control equipment.
5.6. Changing the type of gas supply
In order to adapt the appliance to a new type of gas, disconnect the device (which is not hot!)
from the gas, turn it so that it stands on the back wall (to be able to freely access the interior of the
device from its bottom side). Modifications to the device for supplying a new type of gas may only
be carried out by a person with appropriate permissions.
1. Disassemble the burner assembly by unscrewing it from the mounting, including disconnecting it
from the aluminum gas supply pipe.
2. After removing the burner assembly, mount the desired burner assembly by screwing it in the
same way as its predecessor.
3. Unscrew the gas connector on the back of the device, and then install a new connector.
4. Connect gas to the device. We start the device and then carry out a leakage test around the
components that have been replaced. We carry out the leak test using appropriate leakage testing
measures.
5. After verifying the tightness of the gas system of the device, it is suitable for further use.
5.7. First aid
When providing first aid you should:
• call the appropriate medical services,
• facilitate breathing by removing clothing,
• If necessary, take the injured person into the fresh air,
• cover the injured person with a blanket and prevent them from falling asleep,
• constantly monitor the victim,
• in case the injured person loses consciousness and is not breathing, give artificial respiration until
the arrival of the doctor.
5.8. Warnings
Incorrect handling of the fryer may result in large amounts of gas leaking or poor
combustion, which may cause a fire or poisoning. Poisoning by exhaust gases containing carbon
monoxide or exhaust gases is manifested in tinnitus, heaviness, accelerated pulse, dizziness, vomiting
and general weakness. The injured should receive first aid and call an ambulance.
Any claims against the manufacturer or/and its proxies for damages resulting from the use of the
device contrary to its intended use are excluded.
Liability for damages caused during the use of the device in a manner inconsistent with its intended
use is borne solely by the user.
15