ACV International
10
4.2
Installation location
The appliance should be fitted to a wall that has sufficient bearing strength.
In case of light wall structures the possibility exitsts that resonance noise may occur.
There must be an earthed wall socket within 1 m of the appliance.
If the appliance is installed as an open appliance, the installation location should be
equipped with the necessary openings for the combustion air supply. (See section
5.6.2)
To prevent freezing of the condensate drain pipe, the appliance must be installed in a
frost –free room.
4.2.1
Installing in a kitchen cupboard
The appliance can be installed between two kitchen cabinets or in a cabinet.
Ensure sufficient ventilation at top and bottom. If the appliance is installed in a
cabinet, ventilation openings of at least 50 cm
2
must be created.
4.2.2
Removing cover plate and front panel
For various work on the appliance the cover plate and front panel should be removed
from the appliance. Proceed as follows:
•
If cover plate (A), is used, remove to the front.
•
Unscrew the two screws (1) behind the appliance display cover.
•
Pull the bottom of the front panel (2) forwards.
Summary of Contents for Kompakt HRE eco 12 Solo