SERVICE RECORD

Date installed:

% CO

2

(min. load)

:

% CO

2

(max. load)

:

Gas

LPG

Model :

Serial number :

Heating system pressure setting :

Name and signature :

Flue gas T° :

Efficiency :

Gas pressure :

INSTALLATION DETAILS

Date serviced :

% CO

2

(min. load)

:

% CO

2

(max. load)

:

Gas

LPG

Remarks :

Name and signature :

Flue gas T° :

Efficiency :

Gas pressure :

SERVICE RECORD

Date serviced :

% CO

2

(min. load)

:

% CO

2

(max. load)

:

Gas

LPG

Remarks :

Name and signature :

Flue gas T° :

Efficiency :

Gas pressure :

Date serviced :

% CO

2

(min. load)

:

% CO

2

(max. load)

:

Gas

LPG

Remarks :

Name and signature :

Flue gas T° :

Efficiency :

Gas pressure :

Date serviced :

% CO

2

(min. load)

:

% CO

2

(max. load)

:

Gas

LPG

Remarks :

Name and signature :

Flue gas T° :

Efficiency :

Gas pressure :

Date serviced :

% CO

2

(min. load)

:

% CO

2

(max. load)

:

Gas

LPG

Remarks :

Name and signature :

Flue gas T° :

Efficiency :

Gas pressure :

Summary of Contents for HM 71

Page 1: ...er tube is coated with metal fibre NIT which in addition to its remarkable heat exchange capabilities gives greater durability The main components are a venturi and one model 71 or two model 101 gas v...

Page 2: ...w m3 h 2 46 8 60 3 80 13 17 Gas G31 37 50 mbar I 3P Flow m3 h 0 82 2 86 0 94 4 50 Pressure drop combustion chamber mbar 0 6 1 4 Flue gas temperature net C 172 165 Mass flow rate of combustion products...

Page 3: ...rn OFF the on off switch on the boiler control panel and isolate external electrical supply 2 Turn off the gas supply to the boiler 3 Remove the flue to gain access to the top of the boiler 4 Remove t...

Page 4: ...our installer will have informed you of this value at the time of installation see Commissioning Section Filling the hot water and heating circuits If the pressure falls below 1 bar the boiler water p...

Page 5: ...behind a flap on the front of the boiler see picture on page 16 Standby Mode Standby Mode is the normal operation display setting The first digit shows the boiler sequence This sequence relates to cu...

Page 6: ...ck that sensor NTC2 is propely housed in its pocket if so change sensor NTC2 check that the shunt pump is operating and if so vent the boiler if the fan is turning check the PWM connection if the prob...

Page 7: ...Efficiency Gas pressure SERVICE RECORD Date serviced CO2 min load CO2 max load Gas LPG Remarks Name and signature Flue gas T Efficiency Gas pressure Date serviced CO2 min load CO2 max load Gas LPG Re...

Page 8: ...84 E MAIL sales triangletube com ARGENTINA TECNOPRACTICA ALFEREZ BOUCHARD 4857 1605 CARAPACHAY BUENOS AIRES TEL 54 11 47 65 33 35 FAX 54 11 47 65 43 07 E MAIL jchas tecnopractica com BRAZIL SIMETAL IN...

Reviews: