15

USING THE BOILER

Your system should be serviced at least once a year
by a qualified engineer.
If the boiler is subject to heavy use, it may require
servicing more than once a year - consult your service
engineer for advice.

Starting the burner:
In normal operation, the burner starts automatically
whenever the boiler temperature falls below the set
temperature.

Understanding the control panel

There are no user parts inside the control panel.

Heating system pressure

From time to time you may need to top up the heating
system pressure. This pressure is indicated by the combined
temperature and pressure gauge on the boiler control
panel.

The minimum pressure when the boiler is cold should be
1 bar. The precise operating pressure required depends on
the height of the building, and your installer will have
informed you of this value at the time of installation 

(see

Commissioning Section - Filling the hot water and heating circuits)

.

If the pressure falls below 1 bar, the boiler water pressure
switch will turn the boiler off until pressure is restored.

To re-pressurise, the system needs to be topped up with
water.

First, switch the boiler OFF on the on/off switch and isolate
the external electrical supply. Then remove the casing top
front panel by pulling it forward. The filling valves “A” and
“B” can now be seen. Open both valves and allow the
system to fill. When the combined temperature and
pressure gauge shows the required pressure, close both
valves. Replace the casing top front panel. Restore the
power supply and switch the boiler on.

Safety Valves

If water discharges from any of the safety valves, switch the boiler
off and call a service engineer.

USER GUIDE

On/off switch

Summer/winter switch

Combined temperature and pressure gauge

MCBA controller - display

B

A

Summary of Contents for HM 71

Page 1: ...er tube is coated with metal fibre NIT which in addition to its remarkable heat exchange capabilities gives greater durability The main components are a venturi and one model 71 or two model 101 gas v...

Page 2: ...w m3 h 2 46 8 60 3 80 13 17 Gas G31 37 50 mbar I 3P Flow m3 h 0 82 2 86 0 94 4 50 Pressure drop combustion chamber mbar 0 6 1 4 Flue gas temperature net C 172 165 Mass flow rate of combustion products...

Page 3: ...rn OFF the on off switch on the boiler control panel and isolate external electrical supply 2 Turn off the gas supply to the boiler 3 Remove the flue to gain access to the top of the boiler 4 Remove t...

Page 4: ...our installer will have informed you of this value at the time of installation see Commissioning Section Filling the hot water and heating circuits If the pressure falls below 1 bar the boiler water p...

Page 5: ...behind a flap on the front of the boiler see picture on page 16 Standby Mode Standby Mode is the normal operation display setting The first digit shows the boiler sequence This sequence relates to cu...

Page 6: ...ck that sensor NTC2 is propely housed in its pocket if so change sensor NTC2 check that the shunt pump is operating and if so vent the boiler if the fan is turning check the PWM connection if the prob...

Page 7: ...Efficiency Gas pressure SERVICE RECORD Date serviced CO2 min load CO2 max load Gas LPG Remarks Name and signature Flue gas T Efficiency Gas pressure Date serviced CO2 min load CO2 max load Gas LPG Re...

Page 8: ...84 E MAIL sales triangletube com ARGENTINA TECNOPRACTICA ALFEREZ BOUCHARD 4857 1605 CARAPACHAY BUENOS AIRES TEL 54 11 47 65 33 35 FAX 54 11 47 65 43 07 E MAIL jchas tecnopractica com BRAZIL SIMETAL IN...