ACTpro 1500 and 1520 Operating and Installation Manual
Page 14
6.0 Hardware Installation Guide
6.1 Readers
Diagram 7: Wiring of entry & exit readers.
Reader
terminal block
Recommended
wiring colour
Signal information
SENSE
White
For
Entry readers
connect the reader SENSE cable or
terminal to the SENSE input pin.
For
Exit readers
, do not use this input.
CLOCK
Green
This is the clock or strobe signal input on the ACTpro
1500.
Connect the reader CLOCK cable or terminal on the
reader to CLOCK input pin.
DATA
Blue
This is the Data input.
Connect the reader DATA cable or terminal on the
reader to DATA input pin
+12V
Red
Po12V DC Supply voltage for the reader
0V
Black
0V Supply Voltage for the reader.
RED
Brown
Red LED control output from the ACTpro 1500.
Connect the reader brown cable to the terminal marked
RED on the controller
GREEN
Yellow
Green LED control output from the ACTpro 1500.
Connect the reader green cable or terminal marked
GREEN on the ACTpro controller