16.0  Create a new Database 

 

Select 

File->New->Create

 from ACTWin menu.  

Enter an appropriate 

database name such as “CustomernameAccessDB” and press the 

Save button.   

Installation Wizard: 

Step-1

 

next

  

Step-2

 Select 

ACTpro 1500

 controller and the number of doors installed or to be 

installed. Press 

next

 

Step-3

 Select TCP/IP and enter the controller IP address; if using a USB cable then 

select USB. Press 

next

 

Step-4

 

Finish

 

 

 

 

 

Note:

  

When first installed ACTWin disables the webserver on 
the 1500 controller. To re-enable the Web Server 
feature,  

  Choose the controller 

Database->Controller

  

  Enable the Web Server in the Operation section 

  Save (Record->Accept) 

Summary of Contents for ACTpro 1500

Page 1: ...18 00085 Issue 1 ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply...

Page 2: ...the system it applies to without prior notice While every effort has been taken by ACT to ensure the accuracy of the information contained within this document ACT assumes no responsibility for any er...

Page 3: ...ation Guide 14 6 1 Readers 14 6 2 Push Button PB 15 6 3 Door Contact DC 15 6 4 Break Glass Monitoring only 15 7 0 ACTpro 1500 Controller Status Indicators 16 8 0 ACTpro 1520 Controller Status Indicato...

Page 4: ...database 26 13 3 Export Log events 27 14 0 Installing ACTWin 28 15 0 Run ACTWin for the first time 29 16 0 Create a new Database 30 17 0 Connect to 1500 Controller 31 18 0 Connect ACTWin to more than...

Page 5: ...s ACTpro 1000 2000 3000 or 4000 ACTpro 1520 and 1500 controllers include a web server which allows installers and users to manage installations without requiring ACTWin software If an installation con...

Page 6: ...ler ACTWin software required Diagram 2 Example with ACTpro 1500 and 1520 Controllers Cable Chart From To Network Type Cable Type Max Distance ACTpro 1520 or 1500 PC Ethernet or USB CAT5 or mini USB 10...

Page 7: ...m 2 1 Diagram 3 ACTpro 1500 typical wiring Note For electric strike lock de energized lock wire between Common and Normally open pins Note The ACTpro 1520 is an ACTpro 1500 enclosed in an ACT 12V DC 2...

Page 8: ...defaulted for dynamic IP address DHCP For static fixed IP address set DIP switch 1 to the off position Move DIP switch 1 to the left Default static IP address is 192 168 1 60 Step 2 Open your web bro...

Page 9: ...Step 5 Enable Doors Select Door Settings menu which lists all 32 doors Select door check enable box and enter a door name Press Save Step 6 Logout from installer menu top right corner Step 7 Login to...

Page 10: ...ng and Installation Manual Page 10 Step 8 Add card batch Select Add card batch icon from home screen Enter 1 Enter First card number 2 Enter last card number 3 Set Start user to 1 for a new installati...

Page 11: ...00 controller with ACTpro door stations Doors Network 1 support doors addressed from 2 to 16 Doors Network 2 support doors addressed from 17 to 32 The ACTpro door stations on the Doors network must be...

Page 12: ...or 1520 controller 2 Set DHCP switch 1 to the on position Move switch 1 to the right 3 Reapply power to the controller 5 2 Configuring for Static IP address 1 Remove power from ACTpro 1500 or 1520 co...

Page 13: ...Enter http act1500 folowed by the NetBIOS address e g http act1500 59487 see label on PCB 4 Logon details Username installer Password 999999 5 Choose Communication menu and set the following Static IP...

Page 14: ...obe signal input on the ACTpro 1500 Connect the reader CLOCK cable or terminal on the reader to CLOCK input pin DATA Blue This is the Data input Connect the reader DATA cable or terminal on the reader...

Page 15: ...olts Diagram 9 6 4 Break Glass Monitoring only Connect the normally closed output from one pole of the break glass to the B GL input monitoring terminal on the controller Apply power to the lock via t...

Page 16: ...1500 provides a method to monitor an Emergency break glass switch via the B GL input The fault LED will illuminate if the Emergency break glass switch is activated 3 Mains Fault ACTpro1500 will accept...

Page 17: ...eing supplied to the load The maximum current that the PSU can guarantee is 2A Beyond this the fuse will trip and the LED will stay on until the load is fully disconnected 9 0 Controller Configuration...

Page 18: ...Open Web browser on PC Microsoft Internet explorer Firefox Step3 Enter http act1500 folowed by the NetBIOS address e g http act1500 59487 see label on PCB Static IP address If the ACTpro 1500 or 1520...

Page 19: ...Step 4 Enter new 6 digit code Step 5 Save 9 3 Change User Password Login to the controller as user Login details Username user Password 123456 Change user password Step 1 Login as user Step 2 Go to t...

Page 20: ...tallation Manual Page 20 9 4 Set controller Date and Time Step 1 Login under the user account Step 2 Select setting option top right of screen Step 3 Select Date and Time tab Step 4 Enter correct date...

Page 21: ...le and name door Step 6 Save 10 2 Set Door Relay Timers Step 1 login in as installer Step 2 Select Door Config menu option Step 3 Select desired door Step 4 Select Timers tab Step 5 Enter new time Ste...

Page 22: ...d number Step 3 Enter Last card number Step 4 Set Start user to 1 for a new installation Step 5 Check Enable users Step 6 Save 11 2 Add individual Users Step 1 Select Users from the menu Step 2 Select...

Page 23: ...user group must be created A user group consist of two elements 1 Time zones 2 Door groups 12 1 Create a Time zone To create a Time zone login as user and go to Timezones menu and select a time zone C...

Page 24: ...and Installation Manual Page 24 12 2 Create a Door Group To create a door group 1 Login as user 2 Select Door Groups menu 3 Select available Door Group Assign a unique name to the door group Assign do...

Page 25: ...choose available user group Assign a unique name to the user group e g Finance department Cleaners Enable user group Assign door group and Time zone Save changes 12 4 Assign a user group to a user Sel...

Page 26: ...the PC The backup file is called act1500_snapshot dbo When generating a backup image the controller generates a local snapshot overwriting the previous snapshot 13 2 Restore database The installer ca...

Page 27: ...hot Press the Restore Snapshot button and the database is now fully restored for the backup file For scheduled and unattended backup refer to section Backup Restore from ACTWin 13 3 Export Log events...

Page 28: ...s 7 or Vista right click on ACTWin setup file and select run as administrator then follow the on screen instructions to complete the installation For Windows XP right click on ACTWin setup file and se...

Page 29: ...Directories Tab From the drop down box select the Database Files Database back ups and Log Files and browse to the appropriate directories Press the OK Button to accept the changes and exit the screen...

Page 30: ...next Step 2 Select ACTpro 1500 controller and the number of doors installed or to be installed Press next Step 3 Select TCP IP and enter the controller IP address if using a USB cable then select USB...

Page 31: ...to the controller File Connect from the menu if successfully connected the doors in the system tree will blue green or red Uploading from ACTpro 1500 Controller If the ACTpro 1500 controller has prev...

Page 32: ...ed Each controller must have a unique controller address to change the controller address right click on the controller the select Set Controller number enter a unique number between 1 and 250 Note To...

Page 33: ...Database Backup a backup is created in the backup directory Timed backup 1 Select View Options menu select Program Settings Tab 2 Enable Auto backup database every day at 3 Set the time of the backup...

Page 34: ...ep1 connect to controller File Connect Step2 Select controller from Database Controllers Step3 Select Upgrade and follow on screen instructions to complete the upgrade 21 0 Defaulting Door Station 1 D...

Page 35: ...chain wiring configuration 22 4 Cannot Connect to Controller Step 1 On the 1500 Controller PCB check the Green LINK LED beside Ethernet jack is active if inactive check the network point is connected...

Page 36: ...fault the ACTpro 1500 controller 1 Power down the ACTpro1500 controller 2 Set the Default DIP switch 2 to the ON right position 3 Hold down the Tamper spring 4 Apply power to the ACTpro 1500 controlle...

Page 37: ...and tamper spring is not pressed otherwise the following steps will factory default the controller losing all information 4 Set the DHCP DIP switch to the off position 5 Set the DEFAULT DIP switch to...

Page 38: ...Dimensions 235mm x 165mm x 55mm Weight 455g Relay contacting rating Main relay 5A 50 Vac AUX relay 1A 50 Vac Operating temperature 10 to 50 degrees C Indoor use only Technical Details Capabilities Bre...

Page 39: ...230VAC 10 Frequency 50Hz Input Fuse 625mA 250V anti surge fuse Output Voltage 13 65V 2 Max Load 2A Electronic Output fuse Yes Battery Current 0 5A for a battery discharged to 10V Battery Protections D...

Page 40: ...IP67 rated ACTpro MIFARE 1050e ACT RFID Surface Flush PIN proximity reader IP67 ACTpro MIFARE 1060e ACT PIN only reader ACTpro X MIFARE 1030PM Panel mount multi format proximity reader IP67 ACTpro 103...

Reviews: