29
Screw position in the wall
72.0
Centre Line
Ø 65.0 mm Hole in the wall
Screw position in the wall
Ø 65.0 mm Hole in the wall
Hole With Cone Drill
Indoor Side
Outdoor Side
1. Hook the unit onto the installation plate.
End
Dipped
Into
Water
Water
Leaking
Water
Leaking
Water
Leaking
Wrong
Wrong
Wrong
Drain
Water Drainage
Water
Retention
Correct
Mounting Installation Plate
Ensure that the wall is strong enough to with stand the weight of the unit. Otherwise, it is necessary to reinforce
the wall with plates, beams or pillars. Use the level gauge for horizontal mounting, and fix it with 4 suitable
screws. In case the rear piping draws out, drill a hole 65mm in diameter with a cone drill, slightly lower on the
outside wall (see figure).
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation plate (Engage the two hooks atthe rear top of the
indoor unit with the upper edge of the installation plate). Ensure that the hooks are properly seated on the
installation plate by moving it to the left and right.
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for smooth drainage. Avoid situations that are likely to
cause water to leak.
Summary of Contents for AWSS30A
Page 1: ...Technical Manual WATER COOLED SINGLE SPLIT AWSS30A AWSS40A AWSS50A AWSS60A...
Page 13: ...13 Refrigerant Circuit Diagrams Model AWSS 30 40 50 60A...
Page 63: ...107 Indoor Unit MODEL ACC30C Outdoor Unit MODEL AWSS30A 10 WIRING DIAGRAMS...
Page 64: ...108 Indoor Unit Model ACC40 50 60C Outdoor Unit Model AWSS40 50 60A...
Page 65: ...110 Indoor Unit Model ACK30A Outdoor Unit MODEL AWSS30A...
Page 66: ...111 Indoor Unit Model ACK40 50A Outdoor Unit MODEL AWSS40 50A...