5 Operation
5 .1 Operation and display parts
A – LED display
•
Display of measuring value and operation menu
B - Key Set
•
Access to operation menu
•
In the selection menu entering the selected sub menu
•
In the set menu applying the new value
C - Key Change
•
Change between sub menu
•
Cancel value input without applying
•
Changeover the counter advance sense of the key +/- from + resp. increasing to - resp.
decreasing.
D - Key +/-
•
Value changing by + resp. increasing or - resp. decreasing. The counter advance sense is at
first resp. increasing. Change counter advance sense by the key Change.
•
Change setting in a selection menu
E - Unit LED
•
Indication unit by green LED
F - Error indication LED
•
Indication abnormal behavior by red LED
G - Operation LED
•
Indication ready status by green LED
H - Switch condition LED
•
Indication of an active switch output by the respective yellow LED
5 .2 Function modes
5 .2 .1 Run mode
The device records the applied physical measurand and proceeds the chosen functions according to
the set parameter.
The active operation is confirmed by the green operation LED.
The measuring value is displayed in the display window.
The chosen unit is marked through the come on of the respective green unit LED.
The current output and the switch outputs and are driven.
A turned on switch output is signaled by the come on of the respective yellow switch condition LED.
The exceedance of the frame specifications, abnormal operation conditions and also device
malfunctions are displayed by the red error indication LED.