7.0 XBRD-9060 I/O Expander Accessory Module
The optional XBRD-9060 module may be installed in the Upper Site of an air-
cooled XVME-6500 to bring more I/O to the front panel, as well as allow
mSATA SSD modules to be added for storage.
The following I/O is available on the front panel of the XBRD-9060:
•
One Gigabit Ethernet port via a standard RJ-45 connector. When this
port is enabled on the XBRD-9060 module, one of the Ethernet ports
on the P0 connector is disabled.
•
One RS-232 serial port. This port only contains TX/RX signals. It is
brought out on a mini USB-B connector, but an adapter cable is
included with the module for connection using a standard DB-9
connector.
•
Two USB 2.0 ports. These ports use standard USB-A connectors.
The XBRD-9060 also contains 2 mSATA sockets that allow 2 SSD drives to be
added to the XVME-6500 while still remaining within a single VME slot. Using
the software RAID functionality of the QM87 PCH, these drives can even be
setup as a RAID0/1 array if redundancy or extra speed is desired.
7.1 Ordering Information
The XBRD-9060 is only available in a lead-free solder model. The full model