6.5 Environmental Considerations
Operating Temperature:
0°C to 70°C (Standard Air-Cooled models)
1
-40°C to 75°C (Extended Air-Cooled models)
1
1
Measured as Ambient Air Temperature. 300LFM minimum air-flow required. Designed to
meet this temperature specification. Tested under Windows 8.1 with Passmark BurnInTest
V7.1, running CPU, Memory, and 3D Graphics tests simultaneously. During application testing
CPU temp should be closely monitored for max junction temp of 100°C using a program such as
Argus Monitor or Open Hardware Monitor.
Note:
CPU frequency throttling will occur if the CPU Tj temperature reaches
100°C. This is an effective mechanism to keep the unit from overheating. A
small amount of intermittent throttling at higher ambient temperatures is to
be expected and does not greatly affect system performance. For systems
that need maximum performance at higher ambient temperatures and can
handle the XVME-6500 consuming an extra slot, a larger heatsink is available
as an accessory. Consult factory for more information.
WARNING: If airflow is not adequate, throttling can reach maximum and Tj
temperature could exceed 100
C resulting in system instability. This
temperature should be monitored in end user system with user application
software running to determine if final thermal solution is adequate.
Designed to comply with the following:
Relative Humidity:
5% to 95% Non-condensing
Storage Temperature:
-55°C to 105°C
Shock, Non-Operating:
50g peak acceleration, 11ms duration
MIL-STD-202G Method 213B.
Vibration, Operating:
11.96g
RMS
, 50-20,000Hz, each axis,
MIL-STD-202G Method 214A.
EMC Directives:
The XVME-6510 complies with EMC Directive 2014/30/EU.
•
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2, Level 2.
Radiated Field Immunity (RFI), per IEC 61000-4-3, Class A.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4. Class A.
Surge Immunity, per IEC 61000-4-5, Class A.
Conducted RF Immunity (CRFI), per IEC 61000-4-6, Class A.
•
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16-2-3 Class A.
Low Voltage AC Mains Port, per CISPR 16-2-3 Class A.