VPX4810 PCIe PMC/XMC 3U Carrier
USER’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 26 -
http://www.acromag.com
- 26 -
www.acromag.com
ENVIRONMENTAL
Operating Temperature/Airflow Requirements
Model
Op. Temp
Airflow Requirements
VPX4810
0
C to 70
C
100 LFM
VPX4810CC
-40
C to 85
C
200 CFM if not installed in a conduction cooled chassis.
VPX4810REDI
-40
C to 85
C
N/A. Must be installed in REDI complaint chassis.
Relative Humidity:
5-95% Non-Condensing.
Storage Temperature:
-55
C to 100
C.
Non-Isolated:
PCI/PCIe bus and field commons have a direct electrical connection.
Conduction Cooled PMC/XMC mezzanine card:
VPX4810CC and VPX4810REDI models comply with
ANSI/VITA 20-2001 (R2005).
Designed to meet the following environmental standards per ANSI/VITA47-2005(R2007)
Model VPX4810
•
Environmental Class
EAC4
•
Operating Temperature: AC1 (0 to 70
o
C)
•
Non Operating Class: C3
•
Vibration Class: V2
•
Shock 20g
Model VPX4810CC and VPX4810REDI
•
Environmental Class
ECC3
•
Operating Temperature: CC4 (-40 to 85
o
C)
•
Non Operating Class: C3
•
Vibration Class: V3
•
Shock 40g