Troubleshooting
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective PCB
assembly
Replace PCB
assembly
Disconnect the
wire leads from
relay 3 and check
continuity of relay 3
(Operate the unit)
Abnormal
Normal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Check high vol-
tage transformer
Normal
Normal
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Check high vol-
tage diode
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check high vol-
tage capacitor
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 3 and check
continuity of relay 3
(Operate the unit)
Defective PCB
assembly.
Replace PCB
assembly.
NOTE : • Make sure the wire leads are in the correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
TROUBLE 5:
No microwave oscillation even though oven lamp and blower motor run.
(Display operates properly)
Summary of Contents for MenuMaster RFS Subway
Page 1: ...1 Service Training Manual RFS Subway Models RFS 60 Hz August 2011 16400014 ...
Page 3: ...1 Important Safety Information 1 ...
Page 14: ...12 RFS 60 Hz Components Location 4 ...
Page 16: ...14 Disassembly Door removal Disassembly Control panel removal Wire terminals 5 ...
Page 19: ...17 Performance Testing Procedures 6 ...
Page 21: ...19 Component Testing Procedures 7 ...
Page 25: ...23 Troubleshooting 8 ...
Page 31: ...29 Schematic Wiring Diagrams 9 ...
Page 33: ...31 Schematic Wiring Diagram RFS12SW2C WIRING DIAGRAM DANGER HIGH VOLTAGE ...
Page 34: ...32 Wiring Diagram RFS12TSW BTM PRIMARY INTERLOCK SWITCH TAB 1 TAB 2 DANGER ...
Page 35: ...33 Notes ...