16
Disassembly
1. Disconnect power to oven and remove outer case.
2. Disconnect and label wires from controller/timer.
3. Open oven door.
4. Remove screw securing top of control panel to cavity. Lift control panel up and out to release tabs.
Disconnecting Wire Terminals
All wire terminals are locking-type terminals.
Proceed as follows to disconnect wire terminals:
Insulated terminals:
Grasp insulator pod and pull back.
DO NOT PULL ON WIRE.
1 Grasp
Wire
Insulator
Pod
2 Pull
Non-insulated terminals:
Use a small blade screwdriver to depress locking-tab and pull on terminal.
DO NOT PULL ON WIRE.
1 Release
locking-tab
Wire
2 Pull
Control Panel Removal
Summary of Contents for MenuMaster RFS Subway
Page 1: ...1 Service Training Manual RFS Subway Models RFS 60 Hz August 2011 16400014 ...
Page 3: ...1 Important Safety Information 1 ...
Page 14: ...12 RFS 60 Hz Components Location 4 ...
Page 16: ...14 Disassembly Door removal Disassembly Control panel removal Wire terminals 5 ...
Page 19: ...17 Performance Testing Procedures 6 ...
Page 21: ...19 Component Testing Procedures 7 ...
Page 25: ...23 Troubleshooting 8 ...
Page 31: ...29 Schematic Wiring Diagrams 9 ...
Page 33: ...31 Schematic Wiring Diagram RFS12SW2C WIRING DIAGRAM DANGER HIGH VOLTAGE ...
Page 34: ...32 Wiring Diagram RFS12TSW BTM PRIMARY INTERLOCK SWITCH TAB 1 TAB 2 DANGER ...
Page 35: ...33 Notes ...