21
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Electronic Control Panel
Service Test Mode:
Open door, Press and Hold pad 3 for 5
seconds to enter service test mode.
Press Pad 1..................................................
Press Pad 2..................................................
Press Pad 3..................................................
Press Pad 4..................................................
Press Pad 5..................................................
Press Pad 6..................................................
Press Pad 7..................................................
Press Pad 8..................................................
Press Pad 9..................................................
Press Pad 0..................................................
Stop/Reset Pad ............................................
SERVICE appears in the display
Indicates number of hours
magnetron has been turned on
Indicates number of times
magnetron tube has been turned
on and off
Indicates number of door cycles
CLEAR (Press START pad to
reset service data.)
Indicates amperage (Top Mag)
Indicates amperage (Bottom Mag)
RESET (Clear Service Alarm)
N/A
N/A
N/A
Exit Service Test Mode
Error codes:
E-08
..............................................................
E-09
..............................................................
E-10
..............................................................
Replace Control Board
Replace Control Board
Shorted or Open Keypad – Test
and replace if necessary
s
tl
u
s
e
R
g
n
it
s
e
T
t
n
e
n
o
p
m
o
C
n
o
it
a
r
t
s
u
ll
I
Interlock switch assembly
Disconnect wires to switch.
With door open measure resistance from:
Top Monitor – COM (PK) – NO (BL) ........
Btm Monitor – COM (WH) – NO (RD) ......
Top Primary – COM (RD BK) – NC (BN)
Btm Primary – COM (BK) – NC (BL) ........
Secondary – COM (PK) – NC (GN) ........
With door closed measure resistance from:
Top Monitor – COM (PK) – NO (BL) .......
Btm Monitor – COM (WH) – NO (RD) ......
Top Primary – COM (RD BK) – NC (BN)
Btm Primary – COM (BK) – NC (BL) ........
Secondary – COM (PK) – NC (GN) ........
After verifying or replacing the
module, reconnect wires to switch
and check operation of monitor circuit
before operating the oven.
Indicates continuity
Indicates continuity
Infinite
Ω
Infinite
Ω
Infinite
Ω
Infinite
Ω
Infinite
Ω
Indicates continuity
Indicates continuity
Indicates continuity
Lamp receptacle
Test continuity of receptacle terminals.
Indicates continuity with bulb
installed.
Wire Harness
Test continuity
y
ti
u
n
it
n
o
c
s
e
t
a
c
i
d
n
I
s
e
ri
w
f
o
Summary of Contents for MenuMaster RFS Subway
Page 1: ...1 Service Training Manual RFS Subway Models RFS 60 Hz August 2011 16400014 ...
Page 3: ...1 Important Safety Information 1 ...
Page 14: ...12 RFS 60 Hz Components Location 4 ...
Page 16: ...14 Disassembly Door removal Disassembly Control panel removal Wire terminals 5 ...
Page 19: ...17 Performance Testing Procedures 6 ...
Page 21: ...19 Component Testing Procedures 7 ...
Page 25: ...23 Troubleshooting 8 ...
Page 31: ...29 Schematic Wiring Diagrams 9 ...
Page 33: ...31 Schematic Wiring Diagram RFS12SW2C WIRING DIAGRAM DANGER HIGH VOLTAGE ...
Page 34: ...32 Wiring Diagram RFS12TSW BTM PRIMARY INTERLOCK SWITCH TAB 1 TAB 2 DANGER ...
Page 35: ...33 Notes ...