Troubleshooting
Trouble 1:
The following visual conditions indicate a probable failed control circuit.
1. Incomplete segments.
•
Segment missing.
•
Partial segment missing.
•
Digit
flickering
(Note: Slight
flickering
is normal.)
2.
Colon does not turn on or blink.
3. A distinct change in the brightness of one or more numbers in display.
4. One or more digits in the display are not lighting.
5. Display indicates a number dif
ferent from one touched, for example, key in 5 and 3 appears in the displa
y.
6.
Specific
numbers (for example 7 or 9) will not display when
key
pad is touched.
7.
Display does not count down with time blinking or up with clock operation.
8. Display obviously jumps in time while counting down.
9.
Display counts down too fast while cooking.
10.
Each indicator light does not turn on after setting cooking cycle.
11. Display time of day does not reappear when
cooking
is
finished.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Everything works
Continuity.
No continuity.
Still have trouble.
Defective key
membrane
assembly.
Defective PCB
assembly.
Loose
connection.
Defective PCB
assembly.
Replace key
membrane
assembly.
Replace PCB
assembly.
Connect them
tightly.
Replace PCB
assembly.
Replace key
membrane
assembly and
check operation.
Check the conn-
ection between
membrane key
assembly and
PCB assembly.
2. Some inputs
cannot be
programmed.
1. No input can be
programmed.
3. Display shows a
num
e
e
touched.
4. Random
programming
when touching
other pads.
and can not
accept any
input.
Summary of Contents for MenuMaster RFS Subway
Page 1: ...1 Service Training Manual RFS Subway Models RFS 60 Hz August 2011 16400014 ...
Page 3: ...1 Important Safety Information 1 ...
Page 14: ...12 RFS 60 Hz Components Location 4 ...
Page 16: ...14 Disassembly Door removal Disassembly Control panel removal Wire terminals 5 ...
Page 19: ...17 Performance Testing Procedures 6 ...
Page 21: ...19 Component Testing Procedures 7 ...
Page 25: ...23 Troubleshooting 8 ...
Page 31: ...29 Schematic Wiring Diagrams 9 ...
Page 33: ...31 Schematic Wiring Diagram RFS12SW2C WIRING DIAGRAM DANGER HIGH VOLTAGE ...
Page 34: ...32 Wiring Diagram RFS12TSW BTM PRIMARY INTERLOCK SWITCH TAB 1 TAB 2 DANGER ...
Page 35: ...33 Notes ...