![background image](http://html.mh-extra.com/html/acp/dec18m/dec18m_service-manual_2840449024.webp)
Touch Panel Assembly
Continuity is indicated as 100
Ω and
below.
Pin 1: Ground.
1
2
3
4
5
6
7
8
9
Split
10
Pad Traces
1 8 to 10 Continuity
2 7 to 10 Continuity
3 6 to 10 Continuity
4 5 to 10 Continuity
5 4 to 10 Continuity
6 3 to 10 Continuity
7 8 to 9 Continuity
8 7 to 9 Continuity
9 6 to 9 Continuity
0 5 to 9 Continuity
Start 4 to 9 Continuity
Stop 4 to 8 Continuity
Power Lvl 5 to 8 Continuity
X 2 6 to 8 Continuity
Time Entry 7 to 8 Continuity
Controller board
P1 connector used for
touch panel ribbon
Line voltage to control board
J4-1 to J4-
6…………………….
Output drive voltage to triac
Triac terminals………………….
Gate
—T1………………………
Fan relay (controls blower motor,
antenna motor(s), and oven light)
Terminals J4-1
—J2-2………….
Cook relay
Control board E1
—E4……………
Line voltage (All Conditions)
0 VAC (Idle and Standby)
0.9 VAC (Cook)
Line voltage (Standby and Cook)
0 volts (Idle)
Line voltage (Idle)
0 volts (Standby and Cook)
Summary of Contents for DEC18M
Page 3: ...1 Important Safety Information 1 ...
Page 7: ...2 Oven Specifications 5 ...
Page 9: ...3 Quick Start Reference Guide 7 ...
Page 10: ......
Page 11: ......
Page 12: ...4 Components 10 ...
Page 14: ...DOOR DOOR ASSEMBLY COMPLETE HANDLE WELDMENT INNER DOOR WINDOW HINGES LATCH SPRING ...
Page 18: ...5 Airflow 16 ...
Page 20: ...6 Component Testing 18 ...
Page 27: ...7 Wiring and Schematic Diagrams 25 ...
Page 28: ...DEC18M P2003838M DEC18MC P2003840M DEC18MU P2003839M ...
Page 29: ...DEC18MCX P2003841M ...
Page 30: ...MDC18MT P2003842M ...
Page 31: ...NOTES PAGE 16400030 Revision 0 August 2016 29 ...