COM
Transformer
#
4
#
1
#
2
#
5
#
6
#
7
#
8
Discharge Capacitor
Remove all wires from terminals, and
measure resistance from:
230 to Common ..............................................
Terminal 5 to 6 ................................................
Terminal 7 to 8 ................................................
Terminal 4 to Earth screw on
transformer .....................................................
Terminal 4 to any other terminal ......................
1
Ω.
<1
Ω.
<1
Ω.
38
Ω.
Infinite
Interlock switch
assembly
Disconnect wires to switch.
With door open measure resistance
from:
Monitor
– Terminals 3 - 4 .................
Primary
– Terminals 1 - 2 .................
Secondary
– Terminals 5 - 6 ............
With door closed measure resistance
from:
Monitor
– Terminals 3 - 4 .................
Primary
– Terminals 1 - 2 .................
Secondary
– Terminals 5 - 6 ............
After verifying or replacing the
module, re-connect wires to switch
and check operation of monitor
circuit before operating the oven.
Indicates continuity
Infinite
Infinite
Infinite
Indicates continuity
Indicates continuity
Summary of Contents for DEC18M
Page 3: ...1 Important Safety Information 1 ...
Page 7: ...2 Oven Specifications 5 ...
Page 9: ...3 Quick Start Reference Guide 7 ...
Page 10: ......
Page 11: ......
Page 12: ...4 Components 10 ...
Page 14: ...DOOR DOOR ASSEMBLY COMPLETE HANDLE WELDMENT INNER DOOR WINDOW HINGES LATCH SPRING ...
Page 18: ...5 Airflow 16 ...
Page 20: ...6 Component Testing 18 ...
Page 27: ...7 Wiring and Schematic Diagrams 25 ...
Page 28: ...DEC18M P2003838M DEC18MC P2003840M DEC18MU P2003839M ...
Page 29: ...DEC18MCX P2003841M ...
Page 30: ...MDC18MT P2003842M ...
Page 31: ...NOTES PAGE 16400030 Revision 0 August 2016 29 ...