Snubber Assembly
Disconnect wires to snubber.
Measure resistance across terminals ..............
Infinite.
Magnetron
Discharge Capacitors
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and
ground.
Between Terminals:
Less than
1
Ω.
Each terminal to ground
measures Infinite resistance.
NOTE:
This test is not
conclusive. If oven does not
heat and all other components
test good replace the magnetron
and retest.
Blower Motor
Remove all wires from motor.
Measure resistance across
coil……………..
Approximately 30
Ω.
Stirrer Motor
Remove all wires from motor.
Measure resistance across
coil…………….
Approximately 25k
Ω.
Earth
Load
Line
Line Filter
Line to Line .....................................................
Load to Load ...................................................
Line to Load ....................................................
Any terminal to Earth.......................................
.8 M
Ω
.8 M
Ω
Continuity
Infinite
Summary of Contents for DEC18M
Page 3: ...1 Important Safety Information 1 ...
Page 7: ...2 Oven Specifications 5 ...
Page 9: ...3 Quick Start Reference Guide 7 ...
Page 10: ......
Page 11: ......
Page 12: ...4 Components 10 ...
Page 14: ...DOOR DOOR ASSEMBLY COMPLETE HANDLE WELDMENT INNER DOOR WINDOW HINGES LATCH SPRING ...
Page 18: ...5 Airflow 16 ...
Page 20: ...6 Component Testing 18 ...
Page 27: ...7 Wiring and Schematic Diagrams 25 ...
Page 28: ...DEC18M P2003838M DEC18MC P2003840M DEC18MU P2003839M ...
Page 29: ...DEC18MCX P2003841M ...
Page 30: ...MDC18MT P2003842M ...
Page 31: ...NOTES PAGE 16400030 Revision 0 August 2016 29 ...