Error Code Table
Error Code
Corrective Action
F1
Replace HV/LV
Board
F2
Replace HV/LV
Board
F3
Replace HV/LV
Board
F4
Replace HV/LV
Board
F5
Replace Touch Panel
F6
Replace HV/LV
Board
Usage Test
The Usage Test is used to access Magnetron Hours, Magnetron Cycles and Door Cycles. Use
the following procedure to access the data:
1. Open door.
2. Press and hold pad
3
for five (5) seconds.
NOTE:
After five (5) seconds, SErv illuminates in the display.
3. Press pad
1
for Magnetron Hours.
4. Press pad
2
for Magnetron Cycles.
5. Press pad
3
for Door Cycles.