background image

Safety Tips

before using the product, read all safety precautions.

If the product is abnormal, or work damaged, do not use.

Do not allow water to enter the controller

prevent sharp objects collision surface of solar modules

ensure proper battery clip connector, to prevent short circuits.

no user license serviceable parts inside. Do not disassemble or attempt to repair it.

Do not touch the exposed electrical conductor entrained battery

Limited Product Warranty-One Years Repair,Replacement and refund Remedy, but
fuse excluded

Force Majeure

Sungols shall not be responsible or liable in any way to the customer or any third-party arising from any non

-performance or delay in performance of any terms and conditions of sale, including this

Limited Warranty

for PV Modules

, due to acts God, war, riots, strikes, warlike conditions, plague or other epidemics, fire, fl

ood, or any other similar cause or circumstance beyond the reasonable control of such Sungold. In such ca

ses, performance Sungold of this Limited Warranty shall be suspended without liability for the period of dela

y reasonably attributable to such causes.

www.ACOPower.com

Power Your Green Life!

105W Foldable solar panel

Summary of Contents for 3x35W

Page 1: ...One pair of the alligator clips is for connecting the battery red for anode black for cathode 3 Be used for fixed the unfolding solar panels 4 To control the output and protect the modules 5 unfolded...

Page 2: ...indicator LED1 LED2 LED3 will flash accordingly 6 Press the button again to set up the exact battery type after the selection stop button operation 5 seconds no flashing lights means complete the set...

Page 3: ...output load load indicator light 2 when the load current exceeds 1 25 times the rated load current of 60 seconds and 1 5 times the rated load current of 5 seconds overload when the load indicator flas...

Page 4: ...up stand for extinguish Ubat stand for battey voltage Battery indicator voltage parameters are 25 12Vsystem parameters 24V system parameters x2 Load switch setting method When the controller is in nor...

Page 5: ...ight in normal flash when the battery is full of charge Load Leds slow flashing Load power exceeds rated power Reduce some AC loads and press the button 3 seconds to recover the controller output Load...

Page 6: ...pe the surface of solar modules to remove the remaining dust and dirt Recommend any guano adhesive should be removed as soon as possible from the surface of solar modules so as not to affect performan...

Page 7: ...and refund Remedy but fuse excluded Force Majeure Sungols shall not be responsible or liable in any way to the customer or any third party arising from any non performance or delay in performance of a...