background image

Battery Indicator Instruction

LED1

LED2

LED3

LED4

system status

Slow flash

×

×

×

battery undervoltage

fast flash

×

×

×

Battery over discharge (off load)

Battery voltage rising process

×

×

12.8V

Ubat

13.4V

×

13.4V

Ubat

14.1V

14.1V 

Ubat

Battery voltage drop process

×

12.8V

Ubat

13.4V

×

×

12.4V

Ubat

12.8V

×

×

×

Ubat

12.4V

Remark: “

”stand for light up “

×

” stand for 

extinguish

“Ubat”stand for battey voltage.

Battery indicator 

(voltage parameters 

are 25

,12Vsystem parameters,

24V system parameters x2)

Load switch setting method

        When the controller is in normal power, press the Setting button to achieve the output control of the 

load. Each time press setting button, the load output will be changed accordingly once off status, only the 

load output is in the open state, USB eloquence have 5V voltage output.

www.ACOPower.com

Power Your Green Life!

105W Foldable solar panel

Summary of Contents for 3x35W

Page 1: ...One pair of the alligator clips is for connecting the battery red for anode black for cathode 3 Be used for fixed the unfolding solar panels 4 To control the output and protect the modules 5 unfolded...

Page 2: ...indicator LED1 LED2 LED3 will flash accordingly 6 Press the button again to set up the exact battery type after the selection stop button operation 5 seconds no flashing lights means complete the set...

Page 3: ...output load load indicator light 2 when the load current exceeds 1 25 times the rated load current of 60 seconds and 1 5 times the rated load current of 5 seconds overload when the load indicator flas...

Page 4: ...up stand for extinguish Ubat stand for battey voltage Battery indicator voltage parameters are 25 12Vsystem parameters 24V system parameters x2 Load switch setting method When the controller is in nor...

Page 5: ...ight in normal flash when the battery is full of charge Load Leds slow flashing Load power exceeds rated power Reduce some AC loads and press the button 3 seconds to recover the controller output Load...

Page 6: ...pe the surface of solar modules to remove the remaining dust and dirt Recommend any guano adhesive should be removed as soon as possible from the surface of solar modules so as not to affect performan...

Page 7: ...and refund Remedy but fuse excluded Force Majeure Sungols shall not be responsible or liable in any way to the customer or any third party arising from any non performance or delay in performance of a...

Reviews: