background image

1. Locate the area sunlit clear without hanging branches or obstacles.

2. Open folding package buckle will unfold folded sheet, solar panels equipment should face the sun

Tip: In order to obtain the maximum output power of solar modules, it is recommended to adjust the solar 

modules based on solar trajectory toward.

3.Replace the battery clip is connected to the battery terminals to ensure that the battery clip is not in contact 

with each other. Red battery clip to positive, black negative battery clamp connection, secure the connection.

4.The battery type setting method

5.Press and hold the program button for more than 5 seconds, the battery indicator LED1, LED2, LED3 will 

flash accordingly.

6.Press the button again to set up the exact battery type, after the selection, stop button operation 5

seconds, no flashing lights means complete the setting, the specific content of the following table indicates

LED1

LED2

LED3

Battery Type

×

×

Sealed Lead Acid Battery

Sealed

×

Colloidal lead-acid batteries

Gel

Opening lead-acid batteries

Flooded

Note: "

" means lights on "

×

" means lights off

7. The load switch setting method

When the controller is normal power, press the Set button to achieve the output control of the load. Each 

press set key once, the load output will be changed accordingly once off status, only the load output is in the 

open state, USB eloquence have 5V voltage output.

1

2

Batt

Solar Panel

Fues

Fues

Load

3

www.ACOPower.com

Power Your Green Life!

105W Foldable solar panel

Instructions

Summary of Contents for 3x35W

Page 1: ...One pair of the alligator clips is for connecting the battery red for anode black for cathode 3 Be used for fixed the unfolding solar panels 4 To control the output and protect the modules 5 unfolded...

Page 2: ...indicator LED1 LED2 LED3 will flash accordingly 6 Press the button again to set up the exact battery type after the selection stop button operation 5 seconds no flashing lights means complete the set...

Page 3: ...output load load indicator light 2 when the load current exceeds 1 25 times the rated load current of 60 seconds and 1 5 times the rated load current of 5 seconds overload when the load indicator flas...

Page 4: ...up stand for extinguish Ubat stand for battey voltage Battery indicator voltage parameters are 25 12Vsystem parameters 24V system parameters x2 Load switch setting method When the controller is in nor...

Page 5: ...ight in normal flash when the battery is full of charge Load Leds slow flashing Load power exceeds rated power Reduce some AC loads and press the button 3 seconds to recover the controller output Load...

Page 6: ...pe the surface of solar modules to remove the remaining dust and dirt Recommend any guano adhesive should be removed as soon as possible from the surface of solar modules so as not to affect performan...

Page 7: ...and refund Remedy but fuse excluded Force Majeure Sungols shall not be responsible or liable in any way to the customer or any third party arising from any non performance or delay in performance of a...

Reviews: