manualshive.com logo in svg
background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

(1)The application of voltage or current exceeding its maximum 

allowable value to the input terminals may result in instrument 
damage. 

(2)The supply of power out of its allowable range may cause fire, 

electric shock or instrument failure. 

(3)The content of this manual may subject to change without prior 

notice for product improvement. 

(4)This manual is carefully prepared. However, if any question  

arises, or any mistake, omission or suggestion is found in the 
content of this manual, contact your nearest our sales agent. 

  (5)After read this manual, please keep it as anytime can see. 
 

1.OUTLINE 

   

The AI-406 BCD input panel indicator is a highly reliable 6 digits 
parallel BCD input indicator based on a one chip LSI. It conforms 
to DIN external standards dimensions of 96mm(W)×24mm(H). 

  This meter is powered by 5V DC and 12V DC and has large 14.2mm LEDS. 

Decimal point selection, data latching and leading zero 
suppression are all externally access able at the carded age 
connector. 

 

2.SPECIFICATIONS

 

 

Model&Code 

Input Level 

Input pull up 

Resistance 

Power 

Supply 

AI-406-11 

3.5V

H

5.0V 

0.0V

L

1.5V 

4.7kΩ 

DC5V 

AI-406-12 

100kΩ 

DC5V 

AI-406-22 

10.0V

H

12.0V 

0.0V

L

2.0V 

100kΩ 

DC12V 

 
●Model No. configuration    ※AI-406-21 is

 

Impropriety 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.COMMON SPECIFICATIONS

 

Maximum Display 

:999999 

Display 

:LED numeric element height, 14.2mm 

Zero Display 

:Leading zero on the upper display are 

not shown 

External control 

:Data Latch; 
  Latch terminal and 0V terminal 

(short) 

  BCD Data Latch Display 

Decimal Points 

:Can be set at desired position 

Operating 
Temperature 

:0 to 50℃ 

Power Supply 

:5V DC±10% MAX.35mA/digit 
  12V DC±10% MAX.33mA/digit 

Dimensions 

:96mm(W)×24mm(H)×96.5mm(D) 

Weight(Unit only) 

:Approx. 0.2 Ibs 

Accessories 

:Instruction Manual and Connector 

 

4.HANDLING

 

4-1 General Caution and Preparation Prior to Operation 

1)This instrument should be used at an ambient temperature between  

0 and 50℃ and humidity of 85% or less, paying special attention 
to dew condensation. 

2)It must be used in an environment free of dust, dirt, gases and 

chemicals harmful to electronic components.  

3)Care should be taken to prevent vibration and shock.  

4-2 Mounting 

   1)Panel mounting 
     Make a rectangular cutout as shown in Fig.1, insert the 

instrument in the panel as shown in Fig.2, and then fully push 
the instrument into the panel (It’s recommended that panel 
thickness be from 1 to 4mm.) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   2)Removal of the PC board 
    Insert a screwdriver into the center on bottom of the meter and 

twist so that the front panel comes. Then, push the printed 
circuit board from the back and pull it out from the front. 
(Fig.3) 

 
  (2)Removal of the PC board 
     Insert a screwdriver into the center on bottom of the meter and 

twist so that the front panel comes off. Then, push the printed 
circuit board from the back and pull it out from the front. 
(fig.3) 

4-3 Connector Connection 
    Insert  the  attached  cardedage  connector  at  the  rear  of  the 

indicator. The connector is provided with an insertion key to make 
sure  that  it  is  not  connected  upside  down.  After  insertion, 
tighten   both sides with the attached screws. 

 1)Power connection 
   Connect power to connector terminals Nos. 17 or U and 18 or V(+). 

Use a DC voltage of 5V±10% (AI-406-11, AI-406-12) and 12V±10% 
(AI-406-22) 

   (Note that because this instrument is not provided with a power 

supply switch, it starts operating when power is supplied.) 

INSTRUCTION MANUAL

 

BCD INPUT PANEL INDICATOR

 

MODEL AI-406 SERIES

 

Caution 

WATANABE ELECTRIC INDUSTRY CO., LTD.

AI-406-

Pull-up Resistors

1:4.7kΩ (TTL level)
2:100kΩ

1:DC5V
2:DC12V

Power supply

Отзывы: