4.9.1. Threat simulator
The
Threat simulator
section will generate an Alarm as if the pod has detected a threat.
Select the Threat that you want to test, Enter the azimuth and elevation (between 0 and -90) in
degree and press the
Alarm
button.
The following action has to done:
● The PTZ camera move to the requested location (Gunshot and Firecracker threat only) if
the camera setup is ok and the pod connected to camera
● The pod send an alarm to the VMS (if the
VMS alarm URL settings
is fill up for the
tested threat)
● The pod send an alarm to the an external equipment (if the
Alarm URL
settings is fill up
on the
Server notification setting
)
● The pod send an alarm on the ATD server (if the
Server address
is complet and the pod
connected to the server)
Remark:
● The Sniper simulation threat will not move the camera
● Use only the implemented threat capability of your pod in the threat simulator. For this
firmware version: Gunshot, Firecracker and Sniper