To setup the communication with the ATD server please complete the following field:
●
Server address
⇒
IP address of the ATD server
●
Server port
⇒
Port of the ATD server
●
Frame record Server address
⇒
IP address of the ATD server, usually identical than
the
Server address
●
Frame record Server port
⇒
Port of the ATD server, usually identical than the
Server
port
To apply the new setting, press the
Save
button and reboot the pod.
Remark:
● The
Device identifier
is the pod Serial Number and can not be modified by user
● The
Alarm URL
is a http command user defined, send in case of threat to an external
device (the same command will be send for each type of threat)
● If the
Frame record Server
is blank then no Frame will be sent to the server. In this
case no raw data are stored
ACOEM
|
ATD-300/ATD-301
|
User Manual FW 1.0.0.4 35