Page 11
09-11-2018 · ACO FUNKI · Tlf. 97119600 · www.acofunki.com
FEEDING SYSTEM
MASTER CHAIN
®
Plastic feed dispensers
Plastic feed dispenser are delivered pre-mounted and ready for use after mounting on the feeding system.
Remove the two clamp straps, then remove the adapter.
Split the adapter into two pieces, then mount around the feed pipe. Place the gate in the trail on the upper part of
the feed box, place it on the feeding system around the adapter, then remount the two clamp straps.
There is no adapter on 60 mm feed pipes. Mount the feed box directly on the feed pipe. The lower part of the feed
pipe may be mounted in four different positions, allowing the outlet to turn.
Sensor switch
Place the sensor between the last feed outlet and the loading hopper, however, not closer than 1.5 metres from a
bend.
The feed pipe must be supported immediately before or after the place where the sensor is located. If the feed
pipe is curved, feed will be left in the pipe that the carriers cannot remove. This will disturb the signal and the
functioning of the sensor.
Mount the sensor on a transparent plastic tube using the appropriate fitting. (see fig. A)
Place the plastic tube on the feeding system using two splicing sleeves.
If several sets of switch sensors are placed close to each other in the same housing section, it is important to
locate the transmitters so that their signals are sent in opposite directions (see fig. A)
The transmitter is marked with red. The ICS T O TP 5/receiver with yellow ICS R 001 TP 5
Transmitter (red)
Receiver (yellow)