DAS-208SA Disk Array User Guide
71
Chapter 6 Array Roaming
DAS-208SA Disk Array offers
Array Roaming
function which allows users to
discharge all hard drives from the original SA-2081 SA and insert them in the
new DAS-208SA Disk Array. This function is necessarily significant when
hardware failure happens.
However, please note the following details to make Array Roaming work
properly.
1. When hardware failure happens to the original SA2081SA Disk Array,
please switch off the power and then discharge all 8-bay hard drives.
2.
Re-insert hard drives in the new SA2081SA Disk Array in the correct
order.
For example, the first hard drive in the original disk array should be
inserted in the first hard drive bay in the new disk array. If you insert the
hard drives in the incorrect order,
all data and information in the hard
drives will be damaged and lost.
3. Power on the new disk array, and wait for several minutes for rebuilding,
so that disk array can continue operation.