Chapter 3 • Physical Components
Push Buttons A and B
Together, these buttons are used to restore the consumer supply. The end customer
must press buttons A and B simultaneously for a configured number of seconds
(the default is 5 seconds) when prompted by the LCD display.
Configuration
The following sections describe the available options for the A and B push
buttons.
Supply Reconnection
This setting adjusts the amount of time the push buttons must be depressed
(simultaneously) in order to reconnect the supply.
Audible Indicators
This setting enables or disables audible indications when the push buttons are
pressed.
Optical Port
The SGM1400-B Series meter has an optical port for local communication. It
supports the IEC 62056-21 optical communication interface standard with a baud
rate of 9,600 bps. The optical port is disabled on meters deployed in field.
LED Indicator
The LED indicator flashes when measuring the consumers load. The LED as
default will flash to indicate forward and reverse kWh but can be reconfigured to
show kVArh.
Default
5 seconds
Minimum
2 seconds
Maximum
10 seconds
Default
Disabled
Disabled
0
Enabled
1
Summary of Contents for SGM1400 Series
Page 2: ......
Page 4: ...ii S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2...
Page 12: ...2 S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2 Aclara Support...
Page 54: ...44 S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2 Billing Data...
Page 94: ...84 S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2 Disposal...