7
15 Rue des Marais 44310 ST Philbert de Gd Lieu – Tel. 02 40 59 95 35 – www.acis-france.com
POMPE SOLUBLOC 2V
SOLUBLOC 2V PUMP
Dual speed pump terminal board
▪ Neither the motor nor any of the live parts must come into contact with water.
▪ Make sure the electrical wires are sheathed.
▪ Check the correct positioning of the cable at the terminal board input in order to avoid any water seeping in through
the wire passage.
3.2
HYDRAULIC SYSTEM
▪ Connect the pump to the hydraulic circuit using the couplings provided.
▪ The pipes must be connected to the couplings and glued in place.
▪ The delivery pipe must be fitted at a right angle and perfectly centred with respect to the outlets to be connected,
so as to avoid the pump and pipe from being subjected to external stresses which could cause them to break,
irrespective of the assembly operations. We recommend a vertical pipe length of approx. 60cm to facilitate the
priming of the pump.
▪ A slight tilt of the suction pipes (2%) will prevent any air pockets from forming.
3.3
OPERATION
▪ The pump should operate without making any noise or vibrations.
▪ Check for any leaks on a regular basis.
▪ Always stop the pump before handling the valve on your filter (6-way) on the swimming pool’s hydraulic circuit.