POMPE SOLUBLOC 2V
SOLUBLOC 2V PUMP
3.4
INTERVENTION
Risk of injury to persons without the required qualifications. Repair and maintenance work must be carried out by
specially trained personnel.
▪ When working on the pump:
- Cut off the electricity supply
- Make sure the switch is set to “off”
- Wait for the motor to have come to a complete stop.
▪ The mechanical seal is a vital component of the pump. It should be replaced with the utmost care. It is advisable to
contact a specialist for this task.
▪ Disassembly/Re-assembly: Take the necessary precautions to avoid trapping your hands or feet.
- Clean and check all parts before reassembling them.
- Replace all worn or damaged parts (imperative).
- Make sure the seals are clean and in the correct position. We recommend you only reposition new seals.
▪ In all spare part orders, please specify: the type of pump (data plate), the pump’s serial number (data plate), the
part’s position number (exploded view), the name of the part (table and exploded view)
5.
WINTERING
▪ The pump must be emptied through the plughole for anti-freezing purposes.
RECOMMISSIONING AFTER WINTER
▪ Proceed as follows:
1 - Cut off the electricity supply.
2 - Insert a flat-headed screwdriver in the slot in the centre of the fan cover.
3 - Rotate the motor shaft manually.
4
- Remove the screwdriver
5
– make sure of the water level inside the pump
5 - Start the pump (see § 3.3 COMMISSIONING, PRIMING).