9
15 Rue des Marais 44310 ST Philbert de Gd Lieu – Tel. 02 40 59 95 35 – www.acis-france.com
POMPE SOLUBLOC 2V
SOLUBLOC 2V PUMP
5.
TROUBLESHOOTING
FAULTS
PROBABLE CAUSES
SOLUTIONS
Weak pump output
Sealed turbine
Do cleaning.
Pressure loss in the suction
Avoid: long pipes, numerous elbows, positioning the pump higher than
the water level, narrow pipes
Incorrect voltage
Make sure the voltage in your supply corresponds to the value
specified on the motor data plate
The motor
stops
Motor overheat
Make sure the fan grid is free of obstacles (at least 30 cm clearance
between the wall and the fan)
Check (Control) the absorbed intensity
Noise/vibration
Cavitation
See paragraph 6
Foreign body (sand, etc)
Dismount, clean, reassemble
6.
MINIMUM OPERATING PRESSURE
Model
Pressure in the
water column
height
Pression in Bar
Pression in grams
SOLUBLOC
2 V
3
0.3
300
Explanation: It is vital that you check the pressures specified above when commissioning the pump. In fact, a pressure
below these minimum values leads to the premature wearing of the pump assembly.
Setting: Close the delivery valve progressively in order to achieve the minimum pressure that corresponds to your model.