![background image](http://html.mh-extra.com/html/acer/vt7200d/vt7200d_test-report_2838250022.webp)
International Standards Laboratory
Report Number: ISL-01A105E
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-18-
8.
Power Frequency Magnetic Field immunity
8.1
Power Frequency Magnetic field immunity test
Port: Enclosure
Basic Standard:
EN61000-4-8
Requirements: 1
A/m
Criteria: A
Orientation:
X, Y, Z
Temperature:
17 degree C
Humidity: 60%
Test Setup
3m
Magnetic Field Antenna (1m x 1m)
To AC
To the
Power
Peripheral
metal ground
To AC main
Source
plane
Supply
Non-Metallic
/
Non-Conducted
Table
80 cm
insulation support
Ground
Wire
Metal Full Soldered Ground Plane
Test Result
Performance of EUT complies with the given specification.
Transient 1000
EUT