International Standards Laboratory
Report Number: ISL-01A105E
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-20-
10.
Harmonics
10.1
Harmonics test
Port: AC
mains
Active Input Power: >75W
Basic Standard:
EN61000-3-2
Test Duration:
3min.
Class: D
Test Procedure
The EUT is supplied in series with shunts or current transformers from a source having the
same nominal voltage and frequency as the rated supply voltage and frequency of the EUT. The
EUT is configured to its rated current with additional resistive load when the testing is performed.
Equipment having more than one rated voltage shall be tested at the rated voltage producing
the highest harmonics as compared with the limits.
Result
Performance of EUT complies with the given specification.