International Standards Laboratory
Report Number: ISL-01A105E
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-1-
1.
General
1.1
Certification of Accuracy of Test Data
The immunity tests which this report describes were conducted by an independent
electromagnetic compatibility consultant, International Standards Laboratory in accordance with
the EN55024:1998 / AS/NZS 4252.1:1994 which include EN61000-4 series regulations, Harmonic
Current Emissions EN61000-3-2: 1995: A1:1998/A2:1998/A14: 2000, and Voltage Fluctuations
EN61000-3-3: 1995.
Equipment Tested
: Personal
Computer
Model/ Type/ Machine Type: VT7200D
Applied by Acer Inc.
Date of test
: 2001/11/20
Test Engineer
: W.H.
Chang
Standard
Comment
Test Results
EN61000-3-2: 1995
A1:1998/A2:1998
/A14: 2000
Harmonic Current Emissions
Complies
EN61000-3-3: 1995
Voltage Fluctuations
Complies
EN61000-4-2: 1995
Electrostatic Discharge
Complies
EN61000-4-3: 1996
Radio-Frequency, Electromagnetic Field
Complies
EN61000-4-4: 1995
Electrical Fast Transient/Burst
Complies
EN61000-4-5: 1995
Surge
Complies
EN61000-4-6: 1996
Conductive Disturbance
Complies
EN61000-4-8: 1993
Power Frequency Magnetic Field
Complies
EN61000-4-11: 1994 Voltage Dips / Short Interruption and
Voltage Variation
Complies
Approve & Signature
---------------------------------------------
L. Y. Soong/Director
This test report accurately contains the test results of the above standards at the time of the test.
The results in this report apply only to the sample(s) tested.
This test report shall not be reproduced except in full, without the written approval of International
Standards Laboratory.