Chapter 4
44
Test Equipment
- IBM PC with XGA resolution (Color Video Signal & Pattern Generator)
- DVD player with Multi-system (NTSC/PAL/SECAM), equipped “component” “S-Video”
and “composite”
- HDTV Tuner or Source (480P, 1080i)
- Minolta CL-100
- Quantum Data 802B or CHROMA2316
- After changing parts, check the information below.
Symptom
Burn-in Time
Normal Repair
2 Hours
NFF
4 Hours
Auto Shutdown
6 Hours
Charge
Parts/Update
Version
Update
Color Wheel
Index
ADC
Calibration
Video
Calibration
Reset Lamp
Use Time
Factory
Reset
EDID
M/B
v
v
v
v
v
v
FW
v
v
v
Color Wheel
v
Lamp Module
v
Test Condition
- Circumstance Brightness : Dark room less than 2.5 lux.
- Inspection Distance : 1.5m~3m for functional inspection
- Screen Size : 60 inches diagonal (wide)
- After repairing each
PD726 / PH730
, the unit should be burn-in (Refer to the table below).
Function Test & Alignment Procedure
No
Item
Steps
1
Service Mode
Please do the following steps to enter Service Mode:
1. Turn on the projector.
2. Press “Power”, “Left” button, “Left” button and “Menu” by
order to enter the Service Mode. (As the following pictures
show)
Guide to Entering Service Mode
“Left” button
2
“Left” button
3
4
Menu
Power
1
Summary of Contents for PD726W
Page 55: ...49 Chapter 5 Chapter 5 Exploded Overview EXPLODED OVERVIEW D C PD726 ...
Page 58: ...Chapter 5 52 ASSY ENGINE BASE MODULE PD726 ...
Page 61: ...55 Chapter 5 ASSY OPTICAL ENGINE MODULE PD726 ...
Page 65: ...59 Chapter 5 ASSY BOTTOM HOUSING MODULE PD726 ...
Page 80: ...Chapter 5 74 EXPLODED OVERVIEW D C PH730 ...
Page 83: ...77 Chapter 5 ASSY ENGINE BASE MODULE PH730 ...
Page 87: ...81 Chapter 5 ASSY OPTICAL ENGINE MODULE PH730 ...
Page 92: ...Chapter 5 86 ASSY BOTTOM HOUSING MODULE PH730 ...