Chapter 4
42
Main Procedure
No
Symptom
Procedure
1
No Power
- Ensure the Power Cord and AC Power Outlet are securely connected
- Check Lamp Cover and Interrupt Switch
- Ensure all connectors are securely connected and aren’t broken
- Check DC-DC
- Check Ballast
- Check Main Board
2
Auto Shut Down
- Check LED Status
a. Lamp LED Light
- Check Lamp
- Check Lamp Driver
- Check Main Board
b. Temp LED Light
- Check Thermal Sensor
- Check Thermal Switch
- Check Fan
c. Color Wheel
- Check Color Wheel
- Check Photo Sensor
d. No Power
- Refer to “No Power” troubleshooting
3
No Image
- Ensure the Signal Cable and Source work as well
(If you connect multiple sources at the same time, use the “Source”
button on the control panel to swtich)
- Ensure all connectors are securely connected and aren’t broken
- Check Main Board
- Check DMD Board
- Check Color Wheel
- Check DMD Chip
- Check Engine Module
4
No Light On
- Ensure all connectors are securely connected and aren’t broken
- Check Lamp Module
- Check DC-DC
- Check Ballast
- Check Main Board
5
Mechanical Noise
- Check Color Wheel
- Check Fan Module
6
Line Bar / Line
Defect
- Sometimes it’s because of the DMD Chip and the DMD Board did
not assemble properly
- Check DMD Board
- Check DMD Chip
- Check Main Board
Summary of Contents for PD726W
Page 55: ...49 Chapter 5 Chapter 5 Exploded Overview EXPLODED OVERVIEW D C PD726 ...
Page 58: ...Chapter 5 52 ASSY ENGINE BASE MODULE PD726 ...
Page 61: ...55 Chapter 5 ASSY OPTICAL ENGINE MODULE PD726 ...
Page 65: ...59 Chapter 5 ASSY BOTTOM HOUSING MODULE PD726 ...
Page 80: ...Chapter 5 74 EXPLODED OVERVIEW D C PH730 ...
Page 83: ...77 Chapter 5 ASSY ENGINE BASE MODULE PH730 ...
Page 87: ...81 Chapter 5 ASSY OPTICAL ENGINE MODULE PH730 ...
Page 92: ...Chapter 5 86 ASSY BOTTOM HOUSING MODULE PH730 ...