Chapter 3 JBOD Configurations
38
Disk Drive Spin Up Sequence
At power on, the LS module will perform its internal start up
initialization routine. Then the LS module will assert the disk drive
START_1 and START_2 motor start signals low for disk drive slots 7
through 13, which will spin up the first 7 disk drives immediately. The
LS module will then assert the disk drive START_2 motor start signal
low and leave the START_1 motor start signal high for disk drive slots 0
through 6 which will command the second seven disk drives to spin up
after a delay of 12 seconds times the modulo 8 value of the numeric
SEL_ID of the disk drive.
Once the enclosure is powered up and all 14 drives are spun up as
depicted above, the enclosure will support immediate drive spin up
with two power supplies present.
Modulo 8
The drive spin up sequence above uses modulo 8 to calculate the spin
up delay. Modulo 8 is determined by:
(SHELF ID x DRIVE NUMBER)/8 = REMAINDER
It is the
REMAINDER
value that is used for the calculation as it is
always between 0 and 7 (hence modulo 8). The drive spin up time can
then be calculated as follows:
REMAINDER x MODE PAGE SETTING = SPIN UP DELAY (
Seconds
)
EXAMPLE:
A typical Mode Page Setting is 12, so if the Remainder = 7, the
Spin Up Delay would be 7 x 12, or 84 seconds.
Summary of Contents for Altos S700 Series
Page 1: ...Altos S700 Series User s Guide ...
Page 6: ...Contents vi ...
Page 16: ...xvi ...
Page 17: ...Chapter 1 Introduction ...
Page 24: ...Chapter 1 Introduction 8 Figure 1 1 Altos S700 Series Tower Model ...
Page 25: ...9 Figure 1 2 Altos S700 Series Rack Model ...
Page 26: ...Chapter 1 Introduction 10 ...
Page 27: ...Chapter 2 Installation and Setup ...
Page 36: ...Chapter 2 Installation and Setup 20 Figure 2 1 Location of Jumpers on LS Module ...
Page 38: ...Chapter 2 Installation and Setup 22 3 Replace the LS module ...
Page 43: ...Chapter 3 JBOD Configurations ...
Page 55: ...Chapter 4 RAID Configurations ...
Page 75: ...Chapter 5 System Monitoring ...
Page 86: ...Chapter 5 System Monitoring 70 ...
Page 87: ...Chapter 6 Installing and Removing Components ...
Page 91: ...75 Figure 6 1 Disk Drive Carrier 18F Cam Lever Push locking tab in this direction to open ...
Page 93: ...77 Figure 6 2 LS Module 0 1 2 3 4 5 Cam Lever Push locking tab in this direction to open ...
Page 97: ...Appendix A Safety Statement Translations ...
Page 105: ...Appendix B Technical Specifications ...
Page 111: ...Appendix C Configuration Loop Diagram ...
Page 116: ...Appendix C Configuration Loop Diagram 100 ...
Page 117: ...Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array ...
Page 122: ...Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array 106 ...