13
Safety Statements
The following safety statements must be read before you install or
operate the Altos S700 Series. For language translations of these
statements refer to Appendix B.
Caution
: This equipment is intended only for installation in a
restricted access location.
Caution
: Before attempting to install or remove any of the
components, ensure that anti-static precautions are taken. The
minimum requirement is, a properly grounded anti-static wrist
strap and ground wire.
Caution
: If any of the components are removed the resulting hole
must be blocked, by installing a component blank or replacing the
component. Failure to do so can seriously restrict air flow and
cooling.
Caution
: This device should be connected to a power source
which carries a fuse or circuit breaker that is greater than the
rating of the shelf, but also complies with national wiring
standards.
Caution
: Allow disk drives and power supplies to reach room
ambient temperature before powering on the shelf.
Caution
: It is recommended that, if interconnecting equipment
resides within more than one equipment rack cabinets, these
equipment racks should be at the same ground potential.
Summary of Contents for Altos S700 Series
Page 1: ...Altos S700 Series User s Guide ...
Page 6: ...Contents vi ...
Page 16: ...xvi ...
Page 17: ...Chapter 1 Introduction ...
Page 24: ...Chapter 1 Introduction 8 Figure 1 1 Altos S700 Series Tower Model ...
Page 25: ...9 Figure 1 2 Altos S700 Series Rack Model ...
Page 26: ...Chapter 1 Introduction 10 ...
Page 27: ...Chapter 2 Installation and Setup ...
Page 36: ...Chapter 2 Installation and Setup 20 Figure 2 1 Location of Jumpers on LS Module ...
Page 38: ...Chapter 2 Installation and Setup 22 3 Replace the LS module ...
Page 43: ...Chapter 3 JBOD Configurations ...
Page 55: ...Chapter 4 RAID Configurations ...
Page 75: ...Chapter 5 System Monitoring ...
Page 86: ...Chapter 5 System Monitoring 70 ...
Page 87: ...Chapter 6 Installing and Removing Components ...
Page 91: ...75 Figure 6 1 Disk Drive Carrier 18F Cam Lever Push locking tab in this direction to open ...
Page 93: ...77 Figure 6 2 LS Module 0 1 2 3 4 5 Cam Lever Push locking tab in this direction to open ...
Page 97: ...Appendix A Safety Statement Translations ...
Page 105: ...Appendix B Technical Specifications ...
Page 111: ...Appendix C Configuration Loop Diagram ...
Page 116: ...Appendix C Configuration Loop Diagram 100 ...
Page 117: ...Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array ...
Page 122: ...Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array 106 ...