59
13 Observe the post-installation instructions described on page 36.
To remove the FDD from the optical drive bay:
1
Observe the ESD precautions and pre-installation instructions
described on page 35.
2
Disconnect the data cable from the USB connector on the
backplane board.
3
Press the blue release lever to unlock the FDD tray and remove the
FDD tray assembly from the server.
4
Slide the tray out through the front of the server.
5
Press downward on the side of the tray and disengage the drive
from the two metal tabs on the opposite side of the tray.
6
Lift the FDD out of the tray.
7
Store the FDD tray for future use.
8
Install the filler panel into the drive bay. If installing a new FDD,
see “To install a FDD in the optical drive bay” section on page 56
for installation instructions.
To remove the FDD from a converted HDD bay:
1
Observe the ESD precautions and pre-installation instructions
described on page 35.
2
Disconnect the data cable from the USB connector on the
backplane board
(A)
.
3
Press the blue release latch on the rear of the drive carrier.
4
Slide the drive carrier out through the front of the server
(B)
.
5
Remove the four screws securing the two rails to the carrier, then
lift the rails from the carrier. .
Summary of Contents for Altos R720 Series
Page 1: ...Acer Altos R720 Series User s Guide ...
Page 10: ...x ...
Page 11: ...1 System tour ...
Page 34: ...1 System tour 24 ...
Page 35: ...2 System setup ...
Page 43: ...3 System upgrade ...
Page 107: ...4 BIOS setup ...
Page 143: ...5 Troubleshooting ...
Page 165: ...Appendix A Acer Altos R720 rack installation guide ...
Page 166: ...This appendix shows you how to set up the Altos R720 server in a rack mount configuration ...
Page 178: ...Appendix A Acer Altos R720 rack installation guide 168 ...
Page 179: ...Appendix B SAS hardware RAID configuration ...
Page 180: ...This appendix shows you how to create a RAID volume with integrated SAS hardware RAID ...
Page 186: ...176 ...