AcerAltos 330 Series User’s Guide
3-10
The SCSI controller always checks parity when reading from the SCSI bus to
verify the correct transmission of data from your SCSI devices. You should
disable SCSI Parity Checking if any attached SCSI devices do not support SCSI
parity. (Most currently available SCSI devices do support SCSI parity.)
Use the cursor (
↑
↓
) and Enter keys to make selections. Press Esc at any time to
return to the previous menu.
Host Adapter SCSI Termination
This option allows you to configure host controller SCSI termination. Figure 3-5
shows the choices available if you have an AIC-7880. The default setting is
Enabled
.
Arrow keys to move cursor, <Enter> to select option, <Esc> to exit ( =default)
Adaptec AIC7880 Ultra/Ultra W SCSISelect (TM) Utility
AIC-7880 Ultra/Ultra W at Bus:Device 00:10h
Configuration
SCSI Bus Interface Definitions
Host Adapter SCSI ID ................................ 7
SCSI Parity Checking ................................ Enabled
Host Adapter SCSI Termination .................Enabled
Additional Options
Boot Device Options .................................. Press <Enter>
SCSI Device Configuration ........................ Press <Enter>
Advanced Configuration Options................ Press <Enter>
<F6> - Reset to Host Adapter Defaults
*
*
Enabled
Disabled
Figure 3-5 Host Adapter SCSI Termination Selection for AIC-7880
Use the cursor (
↑
↓
) and Enter keys to make your selection.