background image

General Safety   

2

 Warranty void if product modified, drilled, painted, 
or altered in any way; if used to pump hot water, or 
to pump liquids other than water (such as but not 

limited to chemicals, fertilizers, flammable liquids, 
herbicides, mud, tar, cement, wood chips); or otherwise 
abused.
California Proposition 65 Warning

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, 
birth defects or other reproductive harm.
1.  Before installing or servicing your pump, 

BE CERTAIN 

pump power source is disconnected.

2.  All installation and electrical wiring must adhere to state 

and local codes and must be complete before priming the 
pump. Check with appropriate community agencies, or 
contact your local electrical and pump professionals.

3.  Pump should be installed in a dry, convenient location 

close to the well with ample space for installation and 
servicing the well. A dry basement, pit, or utility room is an 
excellent choice when allowed by law. The pump must be 
securely fastened to a solid foundation. 

The pump should 

always be mounted in a horizontal position on a level 
foundation. Failure to properly secure the pump may 
result in failure of the pump or piping and damage to 
the surrounding area.

4. 

CALL AN ELECTRICIAN WHEN IN DOUBT. Pump motor 
should be connected to a separate electrical circuit directly 
from main switch. There must be a fuse box or circuit 
breaker installed in this line. Plugging into existing outlets 
may cause low voltage at motor, resulting in blown fuses, 
tripping of motor overload, or burned-out motor. 

Refer to 

electrical diagrams for electrical connections.

5.  It is mandatory that a permanent ground connection be 

made from the pump motor to the grounding bar at the 
service panel. Do not connect pump motor to a power 
supply until permanently grounded. For maximum safety, 
ground the pump motor to a circuit equipped with a fault 
interrupter device.

6.  Motor Grounding Instructions: 
 

 Reduced risk of electric shock during 

operation of this pump requires the provision of acceptable 
grounding. 

 

 

Failure to ground this unit properly 

may result in severe electrical shock. If the means of 
connection to the supply-connection box is other than 
grounded metal conduit, ground the pump motor back to 
the service by connecting a copper conductor, at least the 
size of the circuit conductors supplying the pump motor, 
to the grounding screw provided on rib underneath wiring 
compartment cover. NOTE: N.E.C. requires pump motor be 
grounded at installation.

7.   Voltage of power supply must match the voltage of the 

pump. The 2 hp is factory preset to 230V and will not 
operate at any other voltage. However, the 3/4 hp, 1 hp 
and 1-1/2 hp are dual voltage motors. They are preset to 
230 volts, but may be converted to 115 volts, see Figure 1. 

If motor is converted to 115V, an electrician should insure 
electrical and power leads can handle the higher amps.

Power Supply

Terminals

Ground Wire

Terminal

For 115 Volt

For 230 Volt

5730 1107

Figure 1 - Voltage set to 230 volts, Dial Type; turn dial 
to select 115 volts. Insert tool in slot to turn dial.

8.  During installation, cover well to prevent foreign matter 

from contaminating the well or later damaging the pump 
during operation. Test well water for purity. Chlorination 
may be necessary. Check local health department for 
proper testing and recommendations.

9.  Hand pump new wells until clear. 

Pumping sand or other 

sediment will seriously damage the pump and void 
warranty.
 Periodic flushing will remove internal pump 
sediment buildup. TO FLUSH:

•  Remove 1-1/2" plug from top of discharge tee, or remove 

piping if no discharge tee has been installed.

•  Remove 1/4" plug from the lower front of pump.
•  Pour water into top of pump until water flowing from 

lower front of pump is clear.

•  Scrape out any stubborn debris from the lower front 

opening with a wire or pipe cleaner.

•  Reinstall pipes and plugs and reprime before returning 

pump to service.

10. The following may cause severe damage to pump and/or 

piping and will void warranty:

•  Failure to protect pump and piping against below 

freezing temperature.

•  Pumping chemicals or corrosive liquids.
•  Pumping gasoline or other flammable liquids.
•  Using extension cords.
•  Using this pump in or near a swimming pool.
•  Running the pump dry. Follow priming instructions.
•  Discharge pressure not to exceed 100 psi.
•  Torque for pump bolts is 15-20 ft.-lbs.
•  Use of garden hose as discharge or suction line.
•  Failure to securely fastened to a solid foundation.

11.  

 Running the pump without discharge water 

flow will cause serious damage inside the pump due to 
heat buildup. 

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Failure to follow these instructions may cause serious bodily injury and/or property damage.

Summary of Contents for ESP-75A 3/4 HP

Page 1: ...ESP 150A 1 1 2 HP 4039160 ESP 200A 2 HP 4063558 CONSUMER HOT LINE 1 800 422 1551 Monday Friday 7 AM to 5 PM CST INSTALLATION MANUAL Lawn Sprinkler for Inground Sprinkler Systems WARRANTY Product defe...

Page 2: ...to the service by connecting a copper conductor at least the size of the circuit conductors supplying the pump motor to the grounding screw provided on rib underneath wiring compartment cover NOTE N...

Page 3: ...20 35 25 20 ESP 150A 1 5 15 51 48 41 29 106 46 52 20 48 45 40 28 25 43 42 37 27 30 37 35 31 26 35 26 22 ESP 200A 2 0 15 62 53 44 33 107 46 63 20 61 52 43 32 25 60 51 41 31 30 52 48 39 30 35 43 36 27 N...

Page 4: ...ADAPTER 7080 0716 7082 0716 2 The total length of rigid PVC pipe and couplings to cement onto the 1 1 2 male PVC adapter is equal to the operating depth See Determine Operating Depth Cement one sectio...

Page 5: ...e pump 1 1 2 PVC PIPE 7086 0716 8 Using pipe wrench thread 1 1 2 discharge tee into top of pump Remove 1 1 2 plug from top of discharge tee Put a garden hose into top of discharge tee Fill pipes and p...

Page 6: ...TEP 5 Thread 1 1 2 male PVC adapter into the 1 1 2 check valve STEP 6 FOLLOW STEPS 6 13 IN CASED WELL INSTRUCTIONS Total installation should look like the drawing below MULTIPLE WELL POINTS In a well...

Page 7: ...exceeds pump capacity Pump flow in greater than well flow capability Leaks Check all connections for airtightness Suction pipe is too small Should be 1 1 2 pipe Pump loses prime after starting Insuffi...

Page 8: ...ller Kit RPK 7LS for the ESP 75A Kit RPK 10LS for the ESP 100A Kit RPK 15LS for the ESP 150A Kit RPK 20LS for the ESP 200A Kit RPK LSS Includes shaft seal impeller seal slinger gasket 8 3 4 O D gasket...

Page 9: ...ferable and does not apply to products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact ACE Customer Service Sewage...

Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 11: ...HOT LINE 1 800 422 1551 Monday Friday 7 AM to 5 PM CST MANUAL DE INSTALACION Bombas para riego de c sped para sistemas de aspersores subterraneos GARANTIA los defectos de los productos estar n cubiert...

Page 12: ...ue alimentan la bomba al tornillo de toma de tierra provisto en la costilla bajo la cubierta del compartimiento de cableado Vea el diagrama de conexiones NOTA El C digo Nacional El ctrico de los EE UU...

Page 13: ...e especifique lo contrario ESPECIFICACIONES GUIA DE SELECCION DEL CABLE EN Y PARA FUSIBLES DISYUNTORES CAPACIDADES DE LA BOMBA Modelo de bomba HP Presion de descarga PSI Capacidad en gaumin para la pr...

Page 14: ...a cil ndrica RECORDATORIO TODAS LAS JUNTASY CONEXIONES DEBEN QUEDAR HERMETICAS INCLUSO UNA FUGA PEQUE ISIMA IMPEDIRIA EL FUNCIONAMIENTO CORRECTO DE LA BOMBA USAR COMPUESTO PARA ROSCAS EN TODAS LAS CON...

Page 15: ...varios minutos 9 Enrosque el tap n de 1 1 2 de la parte superior de la te de descarga 10 Complete todas las conexiones el ctricas como se especifica en la p gina 2 de las instrucciones anter ores a l...

Page 16: ...o de 1 1 2 PASO 5 Enrosque un adaptador macho de cloruro de polivinilo de 1 1 2 en la v lvula de retenci n de 1 1 2 PASO 6 SIGA LOS PASOS DEL 6 AL 13 DE LAS INSTRUCCIONES DE LOS POZOS POCO PROFUNDOS C...

Page 17: ...lvula de aspiraci n o la punta coladora est obstruida La altura de descarga es demasiado alta La profundidad del pozo excede la capacidad de la bomba El caudal de la bomba es mayor que el rendimiento...

Page 18: ...K 7LS para ESP 75A Juego RPK 10LS para ESP 100A Juego RPK 15LS para ESP 150A Juego RPK 20LS para ESP 200A Juego RPK LSS lncluye el sello del eje sello de impulsor anillo recogelubricante junta de 8 3...

Page 19: ...o cubre productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Ate...

Page 20: ......