background image

Installation & Operation Manual - Model AVC4000 

Contents of this Manual are Subject to Change Without Notification

 

Page   27 

6.5.9.1.3

 

Print 
Parameters Report 

prints a timestamped PDF document of the primary 

configuration parameters which reside in the AVC controller’s 

nonvolatile 

(FLASH) memory. 

6.5.9.1.4

 

Exit 

Closes the Dashboard and disconnects the communications. 

6.5.9.2

 

Controller ID 

 

6.5.9.3

 

Tools 

6.5.9.3.1

 

Close Active Window After Update 

If this item is checked, the active window will automatically close after the 
change has been saved.  If this item is not checked, the active window will 
remain open until the user closes the window.

 

6.5.9.3.2

 

Airflow Measurement 

provides viewing access to the AVC’s real

-time airflow 

measurement data window.  In addition to providing the factory calibration 
constants, the Airflow Window also provides the real-time vortex shedding 
frequency measurement in each chamber of the AccuValve, which can be a 
useful troubleshooting tool.  This window does not provide access for making 
changes to the calibration data. 

6.5.9.3.3

 

Airflow Units

 provides a means to set the units for Airflow Volume for BACnet, 

the Monitor and the AccuValve Insight UI.   Each item can be configured to 
provide different units.

 

 

 

 

Summary of Contents for AccuValve AVC4000

Page 1: ...of this Manual are Subject to Change Without Notification Manufactured by Accutrol Representative AVC4000 MANUAL REV B 2022 03 04 ECN 2772 21 Commerce Drive Danbury CT 06810 USA WWW ACCUTROLLLC COM Ai...

Page 2: ...ainst defects or damages arising from improper installation where installation is by persons other than Manufacturer against defects in products or components not manufactured by Manufacturer or again...

Page 3: ...TABLE OF CONTENTS LIMITED WARRANTY ii TABLE OF CONTENTS iii SECTION 1 INTRODUCTION 4 SECTION 2 SPECIFICATIONS 5 SECTION 3 PHYSICAL DIMENSIONS WEIGHTS 11 SECTION 4 INSTALLATION 12 SECTION 5 WIRING 15 S...

Page 4: ...ty The vortex shedding airflow sensors provide a highly repeatable digital pulse train with a frequency that is directly proportional to the air flow velocity in each chamber of the AccuValve The digi...

Page 5: ...316ss 20 Ga 4 Aluminum 16 Ga VALVE SIZE 06 6 Diameter 08 8 Diameter 10 10 Diameter 12 12 Diameter 14 14 Diameter 18 12 h x 18 w 24 12 h x 24 w ACTUATOR 17 Fail Last Position FLP 10 sec full cycle OPT...

Page 6: ...Current or Resistance Voltage 0 10v Range Input Impedance 100K ohms Current 0 20mA Range Input Impedance 500 ohms Resistance 0 20K Range 500uA Internal Current Source Digital Inputs 2 dry contact inpu...

Page 7: ...Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may caus...

Page 8: ...5 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 25 50 75 100 125 150 175 200 225 250 275 300 325 Valve DP wc Max Airflow CFM 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 100 150 200 250 300 350 400 450...

Page 9: ...CFM 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 300 600 900 1200 1500 1800 2100 2400 2700 Valve DP wc Max Airflow CFM 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 400 800 1200 1600 2000 24...

Page 10: ...s of this Manual are Subject to Change Without Notification Page 10 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 500 1000 1500 2000 2500 3000 3500 4000 Valve DP wc Max Airflow CFM 12x24 AccuValve...

Page 11: ...num Flange Add in mm in mm in mm Lbs kg Lbs kg Lbs kg 06 5 88 149 22 559 10 254 13 5 9 9 4 1 2 0 0 9 08 7 88 200 24 610 13 330 16 7 3 12 5 4 2 6 1 2 10 9 88 250 24 610 15 381 20 9 1 14 6 4 3 2 1 5 12...

Page 12: ...that will provide a minimum clearance of 14 356mm unobstructed access to the control module actuator and valve access cover 3 Provide an opening in the duct section sized appropriately for the valve...

Page 13: ...ning 3 Slip the discharge end of the valve into the duct engaging valve into duct 1 at each end 4 Position valve to provide unobstructed access to the control module actuator and access panel 6 Secure...

Page 14: ...l valve If the duct ends are not square and true do not attempt to install valve as it will not operate properly 2 Lift valve into position to provide unobstructed access to the control module actuato...

Page 15: ...nug 6 Reinstall cover Wiring Instructions 1 Remove cover Bluetooth Antenna W Option Only 5 2 Control Module Wiring Diagram Connections will vary based on application SW 1 NOTE Connections will vary ba...

Page 16: ...nsight Software from http www accutrolllc com Run setup and follow the on screen instructions 6 3 AccuValve Insight Software Product Registration After the software has been installed on your computer...

Page 17: ...ing USB cable 6 4 2 Connecting to AVC4000 W with optional wireless Bluetooth module Note Reference Appendix A for Bluetooth Connection Details AVC4000 W Windows 10 Device with AccuValve Insight Softwa...

Page 18: ...unicate to the AVC4000 W with optional Wireless Bluetooth Module select Locate BT Devices then select the discovered device TAG Name associated with the AVC4000 that you would like to communicate with...

Page 19: ...ume Gauge 2 When the Alarms are not active the Alarm Band Indicator will appear on the gauge however the color will be gray 6 5 4 Airflow Setpoint Gauge The Airflow Setpoint Gauge displays the Airflow...

Page 20: ...ould be configured to receive it s setpoint from Analog Input 1 AI 1 as a 4 to 20mA signal scaled from 0 to 1000 cfm 6 5 5 1 1 Setting Min and Max Volume Limits on the Setpoint When the setpoint sourc...

Page 21: ...nfiguration parameters shown below can be set at the factory if provided by the customer at the time of placing the order NOTE Each AVC Control Module has a unique password which is stored in non vola...

Page 22: ...orrespond with the measured airflow volume Output Full Scale Provides the full scale range of the AO and the corresponding AO Gauge which is 850 cfm for this example Output Signal Type Select from dro...

Page 23: ...ays the Control Output and provides a means for overriding the control loop enabling direct command of the actuator 6 5 6 1 Control Output Override To override the control to Manual 1 Select the OVERR...

Page 24: ...ce the wear and tear on the actuator MEASURED The MEASURED value is the airflow measurement provided by the airflow sensors and is not a configurable parameter The airflow measurement value is the pro...

Page 25: ...lue titled Close Valve when Setpoint ___CFM When the Setpoint is less than this value the controller will drive the valve to the fully closed position 6 5 8 Strip Chart The Strip Chart provides a real...

Page 26: ...valve size specific When using this function verify the configuration file is the correct valve size for the application Clone loads either from a previously existing clone acv6c file or loads from a...

Page 27: ...he change has been saved If this item is not checked the active window will remain open until the user closes the window 6 5 9 3 2 Airflow Measurement provides viewing access to the AVC s real time ai...

Page 28: ...write the factory calibration of the AVC4000 Using this function is not normally required or advisable and is only provided as a tool for the Airflow Balancer to correlate the AVC airflow measurement...

Page 29: ...ed to calibrate the actuator feedback are provided below Step 1 Press the Adaption Button on the Actuator Select OK after Complete Step 2 Select Calibrate 100 Open Position to Drive Valve to the Full...

Page 30: ...Installation Operation Manual Model AVC4000 Contents of this Manual are Subject to Change Without Notification Page 30 6 5 9 4 Help About AccuValve Insight dialog box is shown below...

Page 31: ...upports several standard object types as described herein The following table defines the visible objects The PV column indicates whether the Present_Value is Read Only R Writable W or a Commanded C p...

Page 32: ...ash memory Nonvolatile Flash memory has a limited number of Lifetime Write Cycles Reference Section 7 1 1 for details Note 2 The AVC control module includes a USB port and an optional Bluetooth transc...

Page 33: ...net command prioritization for writable Present_Values AO1 shall include the Priority_Array and Relinquish_Default properties and their corresponding behaviors with respect to controlling the value wr...

Page 34: ...station B AWS BACnet Operator Display B OD BACnet Building Controller B BC BACnet Advanced Application Controller B AAC BACnet Application Specific Controller B ASC BACnet Smart Sensor B SS BACnet Sma...

Page 35: ...nt_Value COV_Increment BI Binary Input No No Inactive_Text Active_Text Object_Name Inactive_Text Active_Text BV Binary Value No No Inactive_Text Active_Text Object_Name Present_Value MSI Multi State I...

Page 36: ...ess translation Yes No Network Security Options Non secure Device is capable of operating without BACnet Network Security Secure Device is capable of using BACnet Network Security NS SD BIBB Multiple...

Page 37: ...3 8 bolt enough to allow the access door to slide forward CAUTION If the bolt is removed from the captive nut the access cover can spring open possibly causing injury 8 1 2 Using two hands squeeze the...

Page 38: ...8 2 1 The access cover is secured to the valve using 4 2 blunt head Phillips head screws To inspect the sensors remove the access cover by removing the screws using a 2 Phillips head screw driver Put...

Page 39: ...e between devices RF interference caused by other devices objects in the area and building construction Because the AccuValve is typically installed in locations that have sheet metal duct work metal...

Reviews: