background image

 

CAUTION:

WARNING:

TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE
THIS PRODUCT TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The lightning flash with arrowhead symbol, within an equilateral triangle,
is intended to alert the user to presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to constitute
a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing) instructions
in the literature accompanying the appliance.

Marking by the “CE” symbol indicates compliance of this device with the EMC
(Electromagnetic Compatibility) and LVD (Low Voltage Directive) standards of
the European Community.

 

 
 
To guarantee a reliable function of this unit over the long-term we kindly ask you to thoroughly 

read 

this instruction manual

 before connecting this unit and to observe the following instructions. This is 

also necessary for your own safety when dealing with the unit. 
 
 
 

2  Important safety instructions 

 
 

 

Read these instructions. 

 

 

Keep these instructions. 

 

 

Follow all instructions. 

 

 

Do not

 use this appliance near water. 

 

 

Never

 use this appliance near hot surfaces. 

 

 

Never

 use this appliance outside and always place it in a dry environment. 

 

 

Check that your mains voltage corresponds to that stated on the appliance. 

 

 

Never

 leave the appliance unsupervised when in use. Always keep electrical equipment out of the 

reach of children. 

 

 

Never

 pour or spill liquids directly onto this appliance. 

 

 

Never

 operate this apparatus in an explosive atmosphere. 

 

 

Do not

 put any vases or similar objects containing water or liquids on top of this appliance. 

 

 

Unplug this appliance during lightning storms or when unused for long periods of time. 

 

Summary of Contents for Power ES

Page 1: ...l 330 VA toroidal core transformer of premium quality for high output reserves separate windings for preamp section for power amp section and for right and left channel Very good smoothing thanks to more than 50 000 µF power supply capacity High damping factor Integrated protective circuit switches ascents off when clipping HF oscillations or too high DC offset occurs Constant low operating temper...

Page 2: ...antee a reliable function of this unit over the long term we kindly ask you to thoroughly read this instruction manual before connecting this unit and to observe the following instructions This is also necessary for your own safety when dealing with the unit 2 Important safety instructions Read these instructions Keep these instructions Follow all instructions Do not use this appliance near water ...

Page 3: ...ergent Never use inflammable or chemically aggressive cleaning agents In the event of a defect please never attempt to repair it yourself Any tampering with the appliance by an unauthorised person will make the warranty void Please get in contact with your authorized dealer Refer all servicing to qualified service personnel Servicing is required when the appliance has been damaged in any way such ...

Page 4: ...erheating of the power amplifier and cause serious damage Therefore leave a minimum of 5 cm distance at the sides and 10 cm distance above the housing cover 5 Installation and start up Fig 1 Rear view of POWER ES without phono module Description of Fig 1 1 Mains power switch 2 FUSE Fuse holder for the main fuse plastic cap with integrated fuse 3 SPEAKER LEFT Left pair of loudspeaker output sockets...

Page 5: ...icates unit is ready for operation 13 PROTECT LED red indicates unit is in protection mode the transmission of a music signal to the connected loudspeaker is interrupted 14 VOLUME Rotary potentiometer for volume setting 5 1 Connection to mains power Only connect the POWER ES to the mains power when all the other cable connections have already been carried out Plug in the mains cable firstly in the...

Page 6: ...se a separate external phono preamplifier To connect a record player you must wire such an external phono preamplifier between the record player and the POWER ES You can activate the individual connected reproduction devices using the rotary switch 10 Please use only high quality interconnect cables This is the only way to ensure that the sound quality of the POWER ES is fully exploited Pin declar...

Page 7: ...e controlled by the surround processor WARNING You can not connect standard units like for example a CD Player to this input In the SURROUND configuration the volume of this input is not controlled this means that the incoming signal is transferred unchanged to the speaker outputs This could otherwise lead to very high volume levels and do serious harm to your connected loudspeakers The SURROUND i...

Page 8: ...lities MM MC On the rear panel of the POWER ES you will find the code switches to configure input 1 The configuration depends on your record player If your record player has a MC system please set both code switches to MC and use the MC input The input impedance for MC systems is fixed to 100 Ω If you need different input impedance please ask your dealer or distributor If your record player has a ...

Page 9: ...er cables For each channel the POWER ES has one pair of high quality loudspeaker terminals Please use only high quality loudspeaker cables This is the only way to ensure that the sound quality of the power amplifier is fully exploited Loudspeaker cables from ACCUSTIC ARTS are excellently matched to the needs of the POWER ES But naturally other high quality brand name products may also be used To c...

Page 10: ... with some other units using a cable please never forget that both units must first be switched off 5 7 Replacing damaged mains fuses If a fuse is damaged only replace the fuse with original types having the same ampere value the same voltage endurance and the same time lag Never use fuses with other ampere classes or time lag classes IMPORTANT Pull out the mains plug Always disconnect the unit fr...

Page 11: ...unt of switch on current is a heavy burden for the electrical components and so the life of the unit will be shortened by this action WARNING During a thunderstorm please completely disconnect the unit from the mains power by pulling out the mains plug 7 Looking after your equipment The POWER ES from ACCUSTIC ARTS does not require special treatment in excess of the usual care taken with high quali...

Page 12: ...do not go out approx 5 seconds after switching on the unit or light up during operation Cause 1 A fuse inside the unit is damaged Solution Pull out the mains plug carefully remove the housing cover and replace the respective fuse This replacement action should only be carried out by the authorized dealer Cause 2 Clipping due to overload of the power amplifier Solution Lower the volume by turning t...

Page 13: ...oad with 1 kHz and 10 watts Signal to noise ratio 89 dBA ref 6 325 V A weighted Damping factor 500 Power consumption 56 VA without load Dimensions 96 x 482 x 400 mm H x W x D 3 8 x 19 0 x 15 7 inches H x W x D Weight approx 11 kg 24 4 lbs 9 2 Additional specifications of POWER ES with optional phono section Inputs 3 x unbalanced high level inputs RCA 1 x unbalanced MM input 1 x unbalanced MC input...