AM8060 Precision Thermometer User’s Guide
30/41
can be set as a multiple of this value, with the multiple ranging
between 1 and 65,535. The instructions for this are as follows:
A.
When AM8060 is in a normal working state, press
MENU
key and
then hold
key for 3 seconds. The AM8060 will display the
main menu as below:
* MAIN MENU *
Wireless Setting
---------------------------------------------
MENU=Quit ENTER=Yes
> U-Drive Setting
Sensor1 Setting
Sensor2 Setting
B.
Press
key or
key to move the cursor line with ”>” sign to
“ > U-Drive Setting”, then press
key to go to the “Record
Cycle adjustment” program, as seen below. “N” represents how
often the temperature will be saved as a multiple of 1.21
seconds. The current value is “1”.
[Record Cycle]
N =
---------------------------------------------
1
MENU=Exit <+ENTER=Adj
C.
To set a sample frequency other than “1”, press and hold
key
while pressing
key, and a display similar to the one below
will appear.
It should be noted that this operation is a two-key
operation. Don’t release the
key before touching
key.