Example
Determine the weight of a sample in extremely unstable ambient conditions by calculating the average of 10 subweighing operations.
Settings (changes in the factory settings required for this example):
Menu: Application program: Weigh Averaging (menu code
2. 1.12
)
Step
Key (or instruction)
Display/Printout
1. Turn on the balance/scale
[ON/OFF]
2. Tare the balance/scale
[ZERO]
0.0
g
3. Display the number
of subweighs
(here: 10)
[F] >2 sec.
ref
10
(briefly)
4. Place sample on the balance/
+
8888
scale (weight readout fluctuates;
here: about 275 g)
5. Start measurement
[F]
+
8888
10
9
8
...
1
After 10 subweighs
+
275.5
g
G
If the print format is set to include
data ID codes, the following is printed:
RES + 275.5 g
6. Unload the balance/scale
+
275.5
g
G
(stable display)
7. Delete the result
[CAL] > 2 sec.
8. Repeat the procedure starting from step 4, if desired.
16