V: 1.0.1  Revised: Nov. 2021

7

www.accuenergy.com

Appendix 

Table 3 - Key Specifications  

SPECIFICATIONS 

Current Range 

0.25A – 100000A 

Range 

50A, 200A, 500A, 2000A, 5000A rated input (field 
configurable) 

Output 

0-1A 

Nominal Current 

1A 

Accuracy 

1% at 1A, 5% at 20A 

Accuracy Limit Factor (ALF) 

20 

Phase Maximum Error 

1 degree 

Class 

5P20 (IEC 61869-2) 

Continuous Thermal Current 

150% (1.5A) 

Short-Time Thermal Current 

20A 

Short-Time Thermal Current Maximum Duration 

4 seconds 

Setting Time to Full Scale 

<100μs 

Operating Temperature 

-25°C to 70°C    /    -13°F to 158°C

Overload Protection 

Thermal 

Operating Humidity 

Non-condensing, 0 to 95% RH 

Mounting 

DIN TS-35/7.5 or 15 (DIN 43880) or Panel 

Measurement Channels 

Frequency Range 

50/60Hz 

Impedance/Burden 

0.25Ω 

Nominal Current 

1A 

Full Scale Maximum Error 

1% @ 1A, 5% @ 20A 

Certifications 

UL Listed (E359521), CE Mark

Appendix

Summary of Contents for RIK 1AR

Page 1: ...RIK 1AR Relay Class Integrator User s Manual ...

Page 2: ...written consent of Accuenergy Canada Inc The information contained in this document is believed to be accurate at the time of publication however Accuenergy Canada Inc assumes no responsibility for any errors which may appear here and reserves the right to make changes without notice Please ask the local representative for latest product specifications before ordering ...

Page 3: ...s that this product is UL Listed Installation and maintenance of the 1AR Rogowski Coil Integrator Kit should only be performed by qualified competent professionals who have received training and show have experience with high voltage and current devices Accuenergy Canada Inc shall not be responsible or liable for any damages caused by improper device installation and or operation Product is protec...

Page 4: ...V 1 0 1 Revised Nov 2021 Table of Contents Chapter 1 Introduction 3 1 1 Overview 3 1 2 What s Included 3 Chapter 2 Installation 4 2 1 Hardware Overview 4 2 2 Installation 5 2 3 Configuration 6 2 4 Measurements 6 Appendix 7 ...

Page 5: ...Hz and 60Hz further increasing its utility across industries 1 2 What s Included The Rogowski Coil Kit includes a single phase integrator unit with five configurable CT ratios for the current input channel and a 24Vdc power supply to power the integrator The integrator can be surface mounted or DIN rail mounted the power supply is designed to be mounted on DIN rail One Rogowski coil model RCTxx 10...

Page 6: ...lation 2 1 Hardware Overview A complete 1AR Rogowski Integrator Kit is comprised of the integrator and power supply mounted on a DIN rail along with one Rogowski coil sold separately Dimensions 4 47 113 5mm 1 42 36 0mm 5 35 136 0mm 2 48 63 0mm 4 93 125 2mm 2 44 62 0mm 3 50 89 0mm 1 89 48 0mm 0 98 25 0mm 4 93 125 2mm 4 47 113 5mm 2 44 62 0mm 3 50 89 0mm 5 35 136 0mm 2 3 4 TB2 1 DC OK V ADJ TB1 1 2 ...

Page 7: ...rown lead to IN The Shield of the Rogowski coil should be left floating Open the coil by pulling apart the black connector of the CT Install the CT around the conductor to be measured Verify the CT is installed with the CT facing the same direction as the current flow direction as indicated by the arrow on the black connector Connect the coil back together Output Connect the output channel to the ...

Page 8: ...able 1 Current Ratio Table 1 2 3 4 5 50 1A ON OFF OFF OFF OFF 200 1A OFF ON OFF OFF OFF 500 1A OFF OFF ON OFF OFF 2000 1A OFF OFF OFF ON OFF 5000 1A OFF OFF OFF OFF ON 2 4 Measurements For each current range the Integrator will be able to measure the current from 0 5 up to 2000 of the rated current When the integrator is configured to measure a current rated for 500A it will measure the current fr...

Page 9: ...20 IEC 61869 2 Continuous Thermal Current 150 1 5A Short Time Thermal Current 20A Short Time Thermal Current Maximum Duration 4 seconds Setting Time to Full Scale 100μs Operating Temperature 25 C to 70 C 13 F to 158 C Overload Protection Thermal Operating Humidity Non condensing 0 to 95 RH Mounting DIN TS 35 7 5 or 15 DIN 43880 or Panel Measurement Channels 1 Frequency Range 50 60Hz Impedance Burd...

Page 10: ...sing Square Suite 700 Toronto ON M2J 4P8 Canada TF 1 877 721 8908 INT 1 416 497 4100 FAX 1 416 497 4130 E marketing accuenergy com Accuenergy South Africa PTY LTD Castle Walk Corporate Park Block B Cnr Nossob Swakop Street Erasmuskloof Pretoria 0181 South Africa TF 27 0 87 802 6136 ...