background image

 

EXM-150 MICROSCOPE SERIES  

 

 

 
 

ACCU-SCOPE

®

     

                   

73 Mall Drive, 

Commack, NY  11725  •  631-864-1000  •  www.accu-scope.com 

4

 

INTRODUCTION 

Congratulations on the purchase of your new ACCU-SCOPE

 ®

 microscope. ACCU-SCOPE

 ®

 

microscopes are engineered and manufactured to the highest quality standards. Your microscope will 
last a lifetime if used and maintained properly. ACCU-SCOPE

 ®

 microscopes are carefully assembled, 

inspected and tested by our staff of trained technicians in our New York facility. Careful quality control 
procedures ensure each microscope is of the highest quality prior to shipment.  
 
 

 

UNPACKING AND COMPONENTS 

Your microscope arrived pre-assembled and packed in a molded container. 

Do not discard the 

container

:  

the molded container should be retained for reshipment of your microscope if needed. Avoid 

placing the microscope in dusty surroundings or in high temperature or humid areas as mold and mildew 
will form. Carefully remove the microscope from the Styrofoam container by its arm and base and place 
the microscope on a flat, vibration-free surface. 

 

 

COMPONENTS DIAGRAM 

 

 

 

Carrying Handle 

Monocular Head 

Eyepiece 

Objective 

Stage 

Disc Diaphragm  

Illuminator 

Housing 

Light Adjustment 

Dial 

Fine Focusing 

Knob 

Coarse Focusing 

 Knob 

 

Nosepiece 

Stage Clip 

Cord Hanger 

Model Shown:  

EXM-150

 

(Models Vary) 

Summary of Contents for EXM-150 SERIES

Page 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com EXM 150 MICROSCOPE SERIES...

Page 2: ...CE 3 INTRODUCTION 4 UNPACKING AND COMPONENTS DIAGRAMS 4 5 ADJUSMENT OPERATION CONNECTING THE POWER CORD 6 ILLUMINATION 6 SPECIMEN SLIDE 7 FOCUSING 7 DISC OR IRIS DIAPHRAGM 8 OIL OBJECTIVE 8 RECHARGING...

Page 3: ...ponent including eyepieces objectives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More pers...

Page 4: ...ighest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived pre assembled and packed in a molded container Do not discard the container the molded container should be retained fo...

Page 5: ...25 631 864 1000 www accu scope com 5 COMPONENTS DIAGRAM Other Models Not Shown EXM 150 MS EXM 151 MST EXM 150 T EXM 151 MS Y Axis Adjustment Top Knob X Axis Adjustment Bottom Knob Condenser Models Fea...

Page 6: ...pe uses a universal power supply so it may be used in any voltage range between 90 240v when used with the appropriate line cord IMPORTANT Use care when storing the power cord so that it does not bend...

Page 7: ...a specimen slide into the slide holder with the cover glass facing up Release the slide finger so it closes and secures the slide in place Rotate the X and Y axis knobs to move the slide into positio...

Page 8: ...cimen slide Rotate the nosepiece so the 100xR oil immersion objective is in the light path Dust or air bubbles in the oil can destroy the definition of the image If the bubbles are trapped between the...

Page 9: ...000A line cord charger and requires approximately 8 hours for a full charge The life expectancy of the rechargeable batteries is approximately 20 000 hours or equivalent to 400 recharges before needin...

Page 10: ...ies 6 Slide the cover back on and replace the screw 7 Close the trap door and tighten the lock screw 8 Carefully place the microscope in an upright position 9 Plug the charger to the power receptacle...

Page 11: ...ck stop position by swinging the objective correctly into the optical path Dirt or dust on the view field Dirt or dust on the lens eyepiece condenser objective collector lens or specimen Clean the len...

Page 12: ...rotating the intensity control dial and or iris diaphragm Insufficient brightness Lamp intensity is too low Aperture diaphragm closed too far Condenser position too low Adjust the light intensity by...

Page 13: ...oes not light when switched on No electrical power Lamp bulb burnt out Fuse blown out Check power cord connection Replace bulb Replace fuse Slippage of focus when using the coarse focusing knob Tensio...

Page 14: ...orkmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user...

Reviews: