MAINTENANCE 

Please remember to 

never

 

leave the microscope with any of the objectives or eyepieces removed and 

always protect the microscope with the dust cover when not in use. 

 
 

 

SERVICE 

ACCU-SCOPE

 ®

 microscopes are precision instruments which require periodic servicing to keep them 

performing properly and to compensate for normal wear. A regular schedule of preventative maintenance 
by qualified personnel is highly recommended. Your authorized ACCU-SCOPE

 ®

 distributor can arrange 

for this service. Should unexpected problems be experienced with your instrument, proceed as follows: 
 
1. Contact the ACCU-SCOPE

 ®

 distributor from whom you purchased the microscope. Some 

problems can be resolved simply over the telephone. 
 
2. If it is determined that the microscope should be returned to your ACCU-SCOPE

 ®

 distributor or to 

ACCU-SCOPE

 ®

 for warranty repair, pack the instrument in its original Styrofoam shipping carton. If you 

no longer have this carton, pack the microscope in a crush-resistant carton with a minimum of three 
inches of a shock absorbing material surrounding it to prevent in-transit damage. The microscope should 
be wrapped in a plastic bag to prevent Styrofoam dust from damaging the microscope. Always ship the 
microscope in an upright position; 

NEVER SHIP A MICROSCOPE ON ITS SIDE

. The microscope or 

component should be shipped prepaid and insured. 

 
 

 

LIMITED MICROSCOPE WARRANTY

 

This microscope and its electronic components are warranted to be free from defects in material and workmanship 
for a period of five years from the date of invoice to the original (end user) purchaser.   The LED lamp is warranted 
for a period of two years from the date of invoice to the original (end user) purchaser.  This warranty does not cover 
damage caused in-transit,  misuse, neglect, abuse or  damage resulting from improper servicing  or modification  by 
other  then  ACCU-SCOPE  approved  service  personnel.    This  warranty  does  not  cover  any  routine  maintenance 
work or any other work, which is reasonably expected to be performed by the purchaser. Normal wear is excluded 
from  this  warranty.  No  responsibility  is  assumed  for  unsatisfactory  operating  performance  due  to  environmental 
conditions  such  as  humidity,  dust,  corrosive  chemicals,  deposition  of  oil  or  other  foreign  matter,  spillage  or  other 
conditions  beyond  the  control  of  ACCU-SCOPE  INC.    This  warranty  expressly  excludes  any  liability  by  ACCU-
SCOPE INC. for consequential loss or damage on any grounds, such as (but not limited to) the non-availability to 
the End User of the product(s) under warranty or the need to repair work processes.  Should any defect in material, 
workmanship or electronic component occur under this warranty contact your ACCU-SCOPE distributor or ACCU-
SCOPE at (631) 864-1000.  This warranty is limited to the continental United States of America.  All items returned 
for warranty repair must be sent freight prepaid and insured to ACCU-SCOPE INC., 73 Mall Drive, Commack, NY  
11725 

– USA.  All warranty repairs will be returned freight prepaid to any destination within the continental United 

States  of  America,  for  all  foreign  warranty  repairs  return  freight  charges  are  the  responsibility  of  the 
individual/company who returned the merchandise for repair.  

 

ACCU-SCOPE is a registered trademark of ACCU-SCOPE INC., Commack, NY 11725 

 

 

 

Summary of Contents for EXM-150 SERIES

Page 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com EXM 150 MICROSCOPE SERIES...

Page 2: ...CE 3 INTRODUCTION 4 UNPACKING AND COMPONENTS DIAGRAMS 4 5 ADJUSMENT OPERATION CONNECTING THE POWER CORD 6 ILLUMINATION 6 SPECIMEN SLIDE 7 FOCUSING 7 DISC OR IRIS DIAPHRAGM 8 OIL OBJECTIVE 8 RECHARGING...

Page 3: ...ponent including eyepieces objectives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More pers...

Page 4: ...ighest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived pre assembled and packed in a molded container Do not discard the container the molded container should be retained fo...

Page 5: ...25 631 864 1000 www accu scope com 5 COMPONENTS DIAGRAM Other Models Not Shown EXM 150 MS EXM 151 MST EXM 150 T EXM 151 MS Y Axis Adjustment Top Knob X Axis Adjustment Bottom Knob Condenser Models Fea...

Page 6: ...pe uses a universal power supply so it may be used in any voltage range between 90 240v when used with the appropriate line cord IMPORTANT Use care when storing the power cord so that it does not bend...

Page 7: ...a specimen slide into the slide holder with the cover glass facing up Release the slide finger so it closes and secures the slide in place Rotate the X and Y axis knobs to move the slide into positio...

Page 8: ...cimen slide Rotate the nosepiece so the 100xR oil immersion objective is in the light path Dust or air bubbles in the oil can destroy the definition of the image If the bubbles are trapped between the...

Page 9: ...000A line cord charger and requires approximately 8 hours for a full charge The life expectancy of the rechargeable batteries is approximately 20 000 hours or equivalent to 400 recharges before needin...

Page 10: ...ies 6 Slide the cover back on and replace the screw 7 Close the trap door and tighten the lock screw 8 Carefully place the microscope in an upright position 9 Plug the charger to the power receptacle...

Page 11: ...ck stop position by swinging the objective correctly into the optical path Dirt or dust on the view field Dirt or dust on the lens eyepiece condenser objective collector lens or specimen Clean the len...

Page 12: ...rotating the intensity control dial and or iris diaphragm Insufficient brightness Lamp intensity is too low Aperture diaphragm closed too far Condenser position too low Adjust the light intensity by...

Page 13: ...oes not light when switched on No electrical power Lamp bulb burnt out Fuse blown out Check power cord connection Replace bulb Replace fuse Slippage of focus when using the coarse focusing knob Tensio...

Page 14: ...orkmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user...

Reviews: