background image

    MANUAL 

73 Mall Drive, Commack, NY  11725  •  631-864-1000 (P)  •  631-543-8900 (F) 

www.accu-scope.com  •  [email protected] 

EXC-500 

MICROSCOPE SERIES 

Summary of Contents for EXC-500

Page 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com EXC 500 MICROSCOPE SERIES...

Page 2: ...GRAMS 4 6 ASSEMBLY DIAGRAM PROCEDURE 7 DETAILED ASSEMBLY 8 10 ADJUSMENT OPERATION POWERING ON 11 ILLUMINATION 11 SPECIMEN SLIDE 11 STAGE STAGE TENSION 11 INTERPUPILLARY DISTANCE 12 LIGHT PATH 12 FOCUS...

Page 3: ...nent including eyepieces objectives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persis...

Page 4: ...ty Careful quality control procedures ensure each microscope is of the highest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded EPE foam container Do not d...

Page 5: ...ower Objectives 2x 4x Fine Focus Adjustment Knob Coarse Focus Adjustment Knob Focus Tension Adjustment Knob Condenser Focusing Knob on both sides Illuminator On Off Button Illuminator Adjustment Knob...

Page 6: ...h Selector Knob Condenser Set Screw ECO Light Control Button Field Aperture Diaphragm 3mm Lamp Housing Set Screw LED Connection Port Power Cord Receptacle Fuse Holder Under Power Cord Receptacle On Of...

Page 7: ...bled by our factory technicians at our New York facility prior to shipment Should you need to disassemble assemble your microscope in the future please follow the instructions outlined below When asse...

Page 8: ...nch Position the condenser with the centering pin facing toward the back of the dovetail slider Slide the condenser into place and wiggle it to ensure the positioning pin is engaged Gently retighten t...

Page 9: ...Viewing Head Fig 7 Using the Hex wrench loosen the lock screw Position the viewing head above the dovetail opening as shown and with it tilted slightly down on the right slide the dovetail under the...

Page 10: ...he LED Lamp Housing Fig 11 Using the Hex wrench loosen the lock screw for the LED lamp housing Align and install the lamp housing with the opening in the back of the stand as shown Retighten the lock...

Page 11: ...15 Push the left side of the Specimen Holder on the top of the stage place to open the holder Place your slide in and release the holder to allow it to close firmly against the slide Adjusting the Sta...

Page 12: ...Where on the eyepiece tube lines up to the interpupillary scale then that is the number for the interpupillary distance Range 47 75mm Remember your interpupillary number for future operation NOTE The...

Page 13: ...e image is in view refine the image to its sharpest focus by turning the fine adjustment knob Rotate the diopter collar to obtain the sharpest focus To obtain the same sharp image using your right eye...

Page 14: ...st the center adjustment screws and move the specimen to the center of the field of view Open the field iris diaphragm gradually If the image is in the center all the time and inscribed to the field o...

Page 15: ...for three 3 seconds Replacing the Fuses Fig 26 27 The fuse holder drawer is located underneath the AC power cord receptacle on the back of the microscope To replace the fuses turn the power off and un...

Page 16: ...on control and upper limit stop to prevent accidental damage to slides all metal gears brass for fine focus gear Stand Cast alloy aluminum Stage Mechanical stage with GorillaTM glass insert and tensio...

Page 17: ...ck stop position by swinging the objective correctly into the optical path Dirt or dust on the view field Dirt or dust on the lens eyepiece condenser objective collector lens or specimen Clean the len...

Page 18: ...ged yellow Lamp intensity is too low Blue filter not used Adjust the light intensity by rotating the intensity control dial and or iris diaphragm Use daylight blue filter Image is too bright Lamp inte...

Page 19: ...ower objective Slide upside down Cover glass is to thick Diopter adjustment is not set properly Turn the slide over so the cover glass faces up Use a 0 17mm cover glass Readjust the diopter settings a...

Page 20: ...mm rotatable 360 Viewing split 100 T 0 B 20 T 80 B and 0 T 100 B WF 10x 22mm focusing eyepieces with eyeguards Reversed sextuple nosepiece NIS Infinity Corrected PLAN 4x 10x 40xR 100xR oil objectives...

Page 21: ...on from 5 to 35 an optional photo video port is available see camera adapters 500 3158 Trinocular viewing head inclined 30 IPD 47 78mm rotatable 360 Viewing split 100 T 0 B 20 T 80 B and 0 T 100 B 500...

Page 22: ...20xR NIS S Plan APO objective N A 0 50 W D 2 1mm 500 3175 SAPO 40xR NIS S Plan APO objective N A 0 75 W D 0 70mm 500 3176 SAPO 100xR NIS S Plan APO objective N A 1 30 W D 0 15mm 500 3221 PH 6 position...

Page 23: ...er 3205 Immersion Oil Type A 1 4 oz Cargille 500 3301 Dust Cover nylon for EXC 500 500 3301 MV Dust cover teaching units F 1CFW 1CF FRAEN 1CFW 1 color fixed light intensity fluorescence illuminator 30...

Page 24: ...rol pod power source See ScopeLED wavelengths below to select wavelengths SLAF OL1 ScopeLED collimating adapter for EXC 500 EXC 350 Specify wavelength required when ordering ScopeLED products 25 LM 75...

Page 25: ...orkmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user...