34
2016/02
Exhaust temp
Ambient temp
Condenser temp
Outlet water temp
Inlet water temp
CODE: 860000000003
Main control board
Running indication
4-way valve
Transformer
High Pressure Switch
Low Pressure Switch
Wire controller
FAN CAPACITOR
CAPACITOR
Power: AC
220-240V/50Hz
To pump
Y
Y
Y
Water flow switch
P3 Inlet water temp sensor failure
P4 Outlet water temp sensor failure
P1 Coil temp sensor failure
P7 Ambient temp sensor failure
P2 Discharge air sensor failure
P8 Too low outlet water temp protection for
cooling mode
PC First step anti-freeze protection in Winter
PC Second step anti-freeze protection in Winter
E4 High pressure protection
P9 Low pressure protection
Pd Water flow switch failure
P6 Too big inlet/outlet water temp difference for
cooling mode
E3 Too high discharge air temp protection
E6 Over heat protection
E8 Communication failure between PCB and wired
control